background image

Product Overview

 363-754-104-01, Revision 01

6

June 22, 1998

 PG-Flex FRC-754 List 4

Ground Start Operation

The following section summarizes the ground start sequences for on-hook (idle), subscriber inititated outgoing 
calls, subscriber received incoming calls, and busy conditions.

Idle Condition. 

Ground start idle condition is a Tip-lead open and Ring-lead negative from the CO and Tip lead 

open and Ring-lead negative at the RT (see 

Table 6

 for circuit interactions). 

Subscriber Initiates Outgoing Call. 

The following occurs when a PBX requests service for an outgoing call 

(see 

Table 7

 for circuit interactions):

PBX grounds Ring lead at the RT

FRC-754 signals the FLC-704

FLC-704 operates a Ring-ground relay that requests dial tone from the CO (this makes the circuit busy, or 
seizes it, for outgoing calls, and blocks any incoming calls prior to the PBX dialing (that is, it prevents glare 
where incoming and outgoing calls may occur simultaneously on the same line). Glare occurs when both ends 
of a telephone line or trunk are seized at the same time.

CO sends dial tone and grounds the Tip to signal the PBX to begin dialing

FLC-704 detects Tip-ground, closes the loop between Tip and Ring, and signals the FRC-754 to send Tip 
ground to the PBX

PBX removes the original Ring-ground condition and completes the loop (Tip and Ring)

Table 6.

Circuit Interactions for an Idle Condition (Ground Start)

Operation

CO Switch

FRC-754 List 4 COCU

FRL-754 List 4 RTCU

Subscriber

Circuit Idle

Tip - no ground
No ringing

Tip - no ground
No ringing

Ring - no ground
On-hook

Ring - no ground
On-hook

Table 7.

Circuit Conditions When a Subscriber Initiates an Outgoing Call (Ground Start)

Operation

CO Switch

FRC-754 List 4 COCU

FRL-754 List 4 RTCU

Subscriber

CO Idle

Tip - No ground
No ringing

Tip - No ground
No ringing

Subscriber requests 
dialtone

Ring - ground
On-hook

Ring - ground
On-hook

CO returns dialtone

Tip - ground
Dialtone

Tip - ground
Dialtone

Subscriber Dials

Ring - no ground
Off-hook
DP or DTMF

Ring - no ground
Off-hook
DP or DTMF

Summary of Contents for PG-Flex FRC-754 L4

Page 1: ...ANNEL REMOTE TERMINAL LOOP START GROUND START POTS UNIT PAIRGAIN TECHNOLOGIES INC ENGINEERING SERVICES TECHNICAL PRACTICE 363 754 104 01J SECTION 363 754 104 01 Model List Number Part Number FRC 754 4...

Page 2: ...n contained in this document is company private to PairGain Technologies Inc and shall not be modified used copied reproduced or disclosed in whole or in part without the written consent of PairGain O...

Page 3: ...4 List 4 June 22 1998 iii USING THIS TECHNICAL PRACTICE Two types of messages identified by icons appear in the text Notes contain information about special circumstances Cautions indicate the possibi...

Page 4: ...Start Operation 4 Ground Start Operation 6 CLASS Features 7 Forward Disconnect 7 Installation and Test ___________________________________________________________________ 8 Unpacking 8 Installing 8 P...

Page 5: ...4 provides metallic access to the subscriber line connection through an optional metallic bypass pair Features of the PG Flex FRC 754 List 4 channel unit are eight loop start or ground start POTS sub...

Page 6: ...ough 8 Fast flashing green Channel is in test access mode Slow flashing green LED follows the ring signal Off Channel is on hook idle FAULT Red Fault detected by the unit See Table 10 on page 10 for t...

Page 7: ...Ringer Output 40 V RMS 3 lines simultaneously 5 REN each End to End Loss 2 5 dB 1 0 dB at 1004 Hz Lightning Protection Meets all requirements GR CORE 1089 Section 4 Environmental Operating Elevation 2...

Page 8: ...subscriber lines or ground start for PBX lines Each FRC 754 List 4 circuit has an associated LED that indicates when the line is off hook idle ringing or under test see Table 1 on page 2 Loop Start Op...

Page 9: ...rcuit interactions Table 3 Circuit Interactions When a Subscriber Initiates an Outgoing Call Loop Start Operation CO Switch FRC 754 List 4 COCU FRL 754 List 4 RTCU Subscriber CO Idle No ringing No rin...

Page 10: ...d outgoing calls may occur simultaneously on the same line Glare occurs when both ends of a telephone line or trunk are seized at the same time CO sends dial tone and grounds the Tip to signal the PBX...

Page 11: ...s activated the CO generates analog signalling toward the PBX between the first and second bursts of the ringing signal Forward Disconnect The forward disconnect function releases a called line that w...

Page 12: ...do not follow the above sequence see Table 10 on page 10 2 After the system has powered up established HDSL synchronized communications and no calls are in progress verify that the channel unit front...

Page 13: ...ss of the call refer to Table 1 on page 2 for front panel indications Place an incoming call to each subscriber circuit provisioned and verify that the ACTIVE LED tracks the progress of the call refer...

Page 14: ...still not present replace the RT Line Unit 3 If ringing is still not present at the RT reinsert the original Channel Unit and Line Unit Test for ringing at the COT 4 Test for ringing into the COT fro...

Page 15: ...ransmission speeds up to 28 8 kbps are supported with a character format of 8 N 1 Warranty PairGain Technologies warrants this product to be free of defects and to be fully functional for a period of...

Page 16: ...ppropriate instruction manual for the unit you are installing to get information on Cabling Correct connections Grounding Modifications The FCC requires the user to be notified that any changes or mod...

Page 17: ......

Page 18: ...Corporate Office 14402 Franklin Avenue Tustin CA 92780 Tel 714 832 9922 Fax 714 832 9924 For Technical Assistance 800 638 0031...

Reviews: