Installation and Test
363-754-104-01, Revision 01
8
June 22, 1998
PG-Flex FRC-754 List 4
I
NSTALLATION
AND
T
EST
Unpacking
Upon receipt of the equipment:
1
Unpack each container and visually inspect it for signs of damage. If the equipment has been damaged in
transit, immediately report the extent of damage to the transportation company and to PairGain. Order
replacement equipment if necessary.
2
Check the contents versus the packing list to ensure complete and accurate shipment. If the shipment is short
or irregular, contact PairGain as described in
. If you must store the equipment
for a prolonged period, store the equipment in its original container.
Installing
1
Insert each FRC-754 List 4 into the FRE-765 RT enclosure, then see if all LEDs on the channel unit:
•
turn ON for approximately 2 seconds
•
scan from top to bottom
•
flash all ON, then OFF
If the LEDs do not follow the above sequence, see
.
2
After the system has powered up, established HDSL synchronized communications, and no calls are in
progress, verify that the channel unit front panel indicators ACTIVE 1 through ACTIVE 8 and FAULT LEDs
are all off.
Provisioning
Provision the FRC-754 List 4 using the appropriate line unit technical practice. For each channel provisioned,
select the loop start of ground start option.
Observe normal electrostatic discharge precautions when handling electronic equipment. Do
not hold electronic plugs by their connector edges. Do not touch components or circuitry.
Observe normal electrostatic discharge precautions when handling electronic equipment. Do
not hold electronic plugs by their connector edges. Do not touch components or circuitry.
Use List 3 of higher PG-Flex CO and RT line units when activating the ground start feature.
To reduce power at the RT, the FRC-754 LEDs turn off after a two minute time-out period. Press
and hold the ACO button on the RT line unit for two seconds to turn on the LEDs for another
two minutes.