Product Overview
363-754-104-01, Revision 01
4
June 22, 1998
PG-Flex FRC-754 List 4
Operational Capabilities
The FRC-754 List 4 channel unit provides eight loop start or ground start POTS interfaces between the RT and
subscribers, and performs the following functions:
•
64 kbps A-Law PCM encoding
•
applies ringing voltage
•
generates forward disconnect
•
generates 12 kHz or 16 kHz meter tones
•
detects an off-hook or ring-trip condition
•
connects a subscriber loop to a metallic bypass pair
•
protects against secondary surges
The subscriber line battery is supplied by a constant current supply. It is sufficient to operate a telephone set over
the indicated loop length. The battery feed can be disconnected and the loop opened to release subscriber
equipment when a forward disconnect signal is received from the FLC-704 List 4 COT line unit. The battery feed
polarity can also be reversed as a physical signal of far end supervision.
Circuit Operation
The following paragraphs define the FRC-754 List 4 circuit operation when using loop start for subscriber lines
or ground start for PBX lines. Each FRC-754 List 4 circuit has an associated LED that indicates when the line is
off-hook, idle, ringing, or under test (see
).
Loop Start Operation
The following section summarizes the loop start sequences for on-hook (idle), subscriber inititated outgoing calls,
subscriber received incoming calls, and busy conditions.
On-hook (Idle) Condition.
Loop start idle condition is a Ring-lead negative and Tip-lead positive from the CO
with the same condition out of the RT toward the subscriber (see
for circuit interactions).
Subscriber Initiated Outgoing Call.
The following occurs when the calling line goes off-hook (see
for circuit interactions):
•
loop current flows and is detected by the FRC-754 List 4 channel unit
•
FLC-704 receives an off-hook signal from the RT
•
FLC-704 generates an off-hook condition to the CO switch
•
CO sends dial tone
•
FRC-754 passes a dial pulse or Dual Tone Multi Frequency (DTMF) signal through the FLC-704 from the
subscriber and forwards these to the CO
Table 2.
Circuit Interactions for an Idle Condition (Loop Start)
Operation
CO Switch
FRC-754 List 4 COCU
FRL-754 List 4 RTCU
Subscriber
Circuit Idle
No ringing
⇒
No ringing
⇒
⇐
On-hook
⇐
On-hook