December 22, 1997
Section 150-219-100-02
HDU-217/219 and
HCC-239 List
1
Page 11
Table 3. Outdoor Enclosure Capacities for the
HDU-219
with Full Solar Load (continued)
Vendor
Description
Model
Number
HDU-
439
Doubler
Capacity
239 T1
Repeater
Capacity
Recommended
Slot
Assignment
for Maximum
Capacity
*
Sierra
Outdoor
canister,
3011
2
6
3, 6
Sunrise
pole/wall
mount
3021
1
5
3
SPC
Outdoor
canister,
7130-
08FP
2
8
4, 6
pole/wall
mount
7130-
12FP
4
12
1, 4, 7, 10
7130-
25FP
6
25
1, 4, 7, 10, 18,
28
† Requires removing the metal slot separator.
* Slot numbers refer to the slots into which a doubler unit may be inserted to
access its four network cable pairs.
6
Decrease any outdoor capacity by one for every four T1
repeaters, or fraction thereof, that are installed with the doublers.
7
Decrease any outdoor capacity by one for every DDS or ISDN
repeater that is installed with the doublers.
8
For all outdoor applications, decrease the capacity by one for
every two adjacent doublers that are not separated by at least one
empty slot.
Always provide as many empty slots between
doublers as possible.