background image

4

SAFETY

SECTION 1

1.1

This manual contains important safety and operating instructions. Please read
these fully and note all warnings before using the charger. Please follow all
instructions and retain this manual for future reference.

1.2

This charger is not intended for any use other than the charging of batteries
as detailed in Section 2, Specification, Range of Batteries Charged.

1.3

IMPORTANT: Use only on AC supplies 100-265V, 50/60Hz. Supply connection
to the unit should be made using only the standard lead supplied with this
equipment.

1.4

Protect the power cord from being walked on or pinched, particularly at plugs.
Unplug this apparatus during lightning storms or when unused for long
periods of time.

1.5

Ensure that the ventilation slots are not obstructed when in use, e.g. do not
site the charger on a carpet, and ensure that nothing covers the charger
when it is in use.

1.6

WARNING: Indoor use only. To reduce the risk of fire or electric shock, do not
expose this apparatus to rain or moisture.

1.7

Although the charger is short circuit protected, extreme care should always
be taken not to short circuit the battery itself. Rechargeable batteries can
deliver power at a very high rate, and short circuiting even a partially
charged battery could result in a fire or personal injury.

1.8

WARNING: This appliance must be earthed.

1.9

Users who are not qualified electronics technicians must not attempt to
disassemble the charger. There are no user-serviceable parts inside, and
incorrect reassembly may result in a safety hazard.

1.10

Do not use the apparatus if it has been damaged in any way, such as the
supply cord or plug is damaged, liquid has been spilled, the apparatus has
been exposed to rain or moisture, does not operate normally, or has been
dropped. In this event you should seek advice from your nearest PAG Dealer,
or direct from PAG Ltd., London, by telep44 (0)20 8543 3131.

Summary of Contents for PAGlink pl16+

Page 1: ...Instruction Manual PL16 CHARGER JAN 2016 ...

Page 2: ......

Page 3: ...3 Instruction Manual CONTENTS SECTION PAGE 1 SAFETY 4 2 SPECIFICATION 5 3 INSTALLATION 7 4 OPERATING INSTRUCTIONS 8 5 SERVICING REPAIRS 10 6 GUARANTEE 11 PL16 CHARGER ...

Page 4: ...covers the charger when it is in use 1 6 WARNING Indoor use only To reduce the risk of fire or electric shock do not expose this apparatus to rain or moisture 1 7 Although the charger is short circuit protected extreme care should always be taken not to short circuit the battery itself Rechargeable batteries can deliver power at a very high rate and short circuiting even a partially charged batter...

Page 5: ...e Model 9303 PAGlink PL96T Model 9304 It is also suitable for parallel charging the following non linking PAG V Mount Li Ion batteries PAG L96e Model 9310 PAG L96T Model 9305 Model 9711A features 4 x Gold Mount battery connectors and is designed for parallel charging the following PAGlink Gold Mount Li Ion batteries individually or linked up to 8 batteries can be linked for charging PAGlink HC PL9...

Page 6: ... will be shut down to a safe condition should any of the tests fail 2 7 Mains Input 100V to 265V AC Frequency 50 60 Hz Maximum consumption 220W 2 8 Output Protection Charger protected against short circuit and excess battery voltage 2 9 AC Mains Failure Protection Should mains failure occur during a charging program or whilst the charger is connected it will shut down to a safe condition 2 10 User...

Page 7: ...eries INTERNATIONAL PATENTS APPLY Gold Mount is a registered trademark of Anton Bauer 7 INSTALLATION SECTION 3 3 1 The charger is fitted with an mains input socket conforming to CEE22 IEC socket Mains supply connection to the charger should be made using only the standard lead supplied with this equipment 3 2 The charger has been designed for use on AC mains supplies worldwide and automatically ac...

Page 8: ...harger display will indicate CHRG on the appropriate channels 4 5 Li Ion batteries are charged simultaneously using PAG s Intelligent Parallel Charging program see Typical Battery Charging Times Section 2 16 NOTE Older generation PAG Li Ion batteries will be charged sequentially 4 6 Up to 8 PAGlink batteries per channel may be charged Batteries can be in any state of charge The most discharged bat...

Page 9: ...ries for charging 4 12 If the charger detects a faulty battery while the charging program is running the display will show FAIL This could be caused by one of several conditions such as a very old or damaged battery a short circuit battery or an excessively high or low voltage battery 4 13 The charger will not recognise the connection of a battery which has a voltage substantially outside of its r...

Page 10: ... FUSE OF THE CORRECT RATING If the replacement of the fuse fails to correct the above symptoms do not attempt further fuse replacement It is likely that a fault has developed Seek advice from your nearest PAG dealer or direct from PAG Ltd London by telephoning 44 0 20 8543 3131 5 4 The chargers feature a fail safe shutdown mode In the unlikely event of an internal malfunction an error message will...

Page 11: ...f the guarantee provided the guarantor s examination discloses to its satisfaction the product was defective The guarantor may at its option replace the product in lieu of repair With regard to any equipment returned within this period said repairs or replacements will be made without charge If the failure has been caused by misuse neglect accident or abnormal conditions of operation repairs will ...

Page 12: ...Charger Models 9711 9711A APPLICABLE EU DIRECTIVES EMC DIRECTIVE 89 336 EU LOW VOLTAGE DIRECTIVE 73 23 EU CE MARKING DIRECTIVE 93 68 EU HARMONISED STANDARDS APPLIED GENERIC EN 50081 1 EMISSIONS EN 50082 1 IMMUNITY PRODUCT SPECIFIC EN 55022 B EN 60555 2 3 IEC 801 2 3 4 EN 60335 1 EN 60335 2 29 Signed for and on behalf of PAG Ltd Alan Lavender Chief Executive Date 20 10 15 PAG Ltd 565 Kingston Road ...

Reviews: