O P E R A T I O N
T6M SERIES MOBILE SERVICE MANUAL – SM/16/1.0
PAGE 5-7
These options are programmable for each of the channels programmed into the mobile.
Range
Default
Notes
Frequency
Any frequency
supported by
the mobile
Enter this in ICAO format,
which defines both the
frequency and the
bandwidth.
Priority
channel
Yes on No
No
Up to 15 channels may be
defined as priority channels.
Scan group
1 – 15 or not
assigned
Not
assigned
to a scan
group.
Up to 15 channels may be
assigned to each of the 15
scan groups. A channel
may be in more than one
group.
Transmit
inhibited
No inhibit,
always inhibit
or inhibit if
busy
No inhibit
This option can be used to
prevent the mobile
transmitting on a particular
channel.
Identification
string
16 character
alphanumeric
string
An empty
string
A free format text string
describing the channel.
5.4 Warning sounds.
Warning sounds may be enabled / disabled when the mobile is programmed.
The volume of key beeps and warning beeps is not affected by the volume controls. The
volume of these sounds is set when the mobile is programmed.
When warning beeps are enabled, the following conditions cause error beeps when the user
attempts to transmit
•
A mobile fault is preventing transmission.
•
Attempting to transmit on a channel with the “transmit inhibit” option set to
always inhibit.
•
Attempting to transmit on a busy channel with the “inhibit if busy” option
selected.
•
Imminent transmitter timeout.