background image

SCAHTUM-03

 

16 

SCA 1200HT User Manual 

7: Unpacking, Inspecting and Installing your SCA 

 

THE SCA SHOULD BE INSTALLED BY AN AUTHORIZED DISTRIBUTOR ONLY.  

INSTALLATION BY THE USER MAY VOID THE WARRANTY. 

Before removing your SCA from its packaging, completely read this manual.  Follow all 
safety recommendations while unpacking, installing and operating the system. 

7.1: Package Contents 

The SCA is shipped with the following contents: 

SCA System (1) 
Large Part Basket (1) 
Small Part Basket (1) 
Quick Reference Card (1) 

Power Cords: 

110V North America std. 
220V Europe std. 

User’s Manual & Warranty (1)

If any parts are missing you should contact customer support immediately. 

7.2: Unpacking 

Place the package on a stable horizontal surface and check inside for the 
items listed above.  Some items may be stored inside the tank for 
shipping. Remove everything from the SCA unit itself before lifting the 
SCA from the shipping container. 

Unit weight is approximately 64 lb/29 kg.  Two or more people should 
lift the unit out of the packaging and place it on a table or cart.  

7.3: Inspecting Unit 

Carefully inspect the unit for damage during shipping.  If any damage is found DO NOT 
ATTEMPT TO OPERATE THE UNIT. Contact technical  support immediately for 
assistance. 

7.4: Installation 

1.

 

Place the Large Part Basket into the tank after ensuring all  packing material  has 
been removed.  

2.

 

Close the lid over the tank. 

3.

 

Attach the power cord to the system and then to a 
grounded wall socket.  Only use a  power  cord 
provided by the manufacturer. 

4.

 

Press  the  ON/OFF  Power  Switch  and check to 
make sure that the display control panel lights up.  

5.

 

Turn the unit off. 

6.

 

Make sure the drain valve is in the closed 
position.  Remove the blue plastic cap from the 
drain tube before use. 

7.

 

Complete  the online  registration  form at 
www.SupportRemoval.com.

Figure 8: Power Switch and Plug Locations

 

Power Switch 

Drain Tube 

Drain Valve 

(closed position) 

Power Cord 

Receptacle 

Summary of Contents for SCA 1200 HT

Page 1: ...SCAHTUM 03 1 SCA 1200HT User Manual User Manual August 1 2016 Phoenix Analysis Design Technologies Inc PADT Inc TEL 1 800 293 PADT FAX 480 813 4807 sca padtinc com www SupportRemoval com...

Page 2: ...SCAHTUM 03 2 SCA 1200HT User Manual This page left intentionally blank...

Page 3: ...4 INSTALLATION 16 8 OPERATING YOUR SCA 17 8 1 FILL THE UNIT WITH WATER 17 8 2 ADD CLEANING CONCENTRATE TO THE TANK 17 8 3 PREHEATING AND STARTING THE CLEANING CYCLE 18 8 4 LOADING PARTS AND TESTING LE...

Page 4: ...hould be easily accessible at all times Position the unit so that it can be easily reached It is strongly recommended that the unit be placed on a circuit with its own breaker with a GFCI Place the un...

Page 5: ...warranty The WaterWorks solution that may be added to the unit to aid in support removal contains Sodium Hydroxide Please read and remember the following safety information about this material DANGER...

Page 6: ...ank before adding large parts to avoid overflow Always operate the unit in a well ventilated location Always operate within environmental temperature range of 10 to 30 degree C Do not use the SCA for...

Page 7: ...se neglect accident improper installation improper maintenance or improper operation or application or if the machine was improperly repaired or serviced by the customer This warranty is void if the s...

Page 8: ...ctromagnetic Compatibility EMC Waste Electrical and Electronic Equipment WEEE Restriction of Hazardous Substances RoHS 2004 108 EC 2012 19 EU 2011 65 EU Common Technical Specifications Used for Demons...

Page 9: ...SCAHTUM 03 9 SCA 1200HT User Manual...

Page 10: ...fic amount of cleaning solution added see operating instructions The SCA heats the water and circulates the heated water around the parts in the tank The hot solution dissolves the support material wi...

Page 11: ...t timer 3 Start Pause 4 No heat selection 5 Temperature selection 6 Silence alarm 7 Alert indicator 8 Low water indicator 9 High water indicator 10 Temperature LED display 11 Pump operating LEDs 12 Pr...

Page 12: ...rinsed after emptying the tank before refilling with fresh liquid The Heater is located behind the perforated Heater Shield It heats the water in the tank The Spray Nozzle directs the flow of liquid i...

Page 13: ...ceptacle is where the power cord is connected to the unit The plug is a disconnecting device and should be easily accessible at all times 6 2 4 Front Area The Drain Tube and Drain Valve are on the fro...

Page 14: ...1 Product Identification Tag The Product Identification tag is located on the back of the unit It contains key support information for the SCA including Model Number Part Number Serial Number and cont...

Page 15: ...ponents in the system Please consult this information when calling for support or ordering replacement parts Figure 7 SCA Assembly Table 1 List of Replaceable Components Large basket Small parts baske...

Page 16: ...before lifting the SCA from the shipping container Unit weight is approximately 64 lb 29 kg Two or more people should lift the unit out of the packaging and place it on a table or cart 7 3 Inspecting...

Page 17: ...Refer to section on Maintaining your SCA for disposal instructions The Ecoworks cleaning agent is both user and eco friendly The WaterWorks concentrate will generally remove support material in less t...

Page 18: ...the SET button and then press the up and down arrows to set the minutes Press the SET button again and use the up and down arrows to set the hours Press the SET button again to accept the time Press t...

Page 19: ...rts can be checked at any time during a cleaning cycle by opening the lid carefully lifting the Large Parts Basket from the tank turning the basket 90 and resting it on the rear support bracket and fr...

Page 20: ...cycle is completed and the parts have been removed the system should be turned off by pressing the ON OFF rocker switch Alternatively if the SCA will be used periodically use the 50 C temperature pres...

Page 21: ...rotective gloves and eyewear when draining the tank You should drain the liquid from the tank if the unit will not be used in the near future or if the liquid needs to be changed out because the clean...

Page 22: ...used solution is sufficient for most applications More dilution may be required please check your local regulations If you are ever unsure as to which solution was used in your SCA assume that the Wa...

Page 23: ...cloth Never immerse the system or use a spray nozzle or hose to clean it Any liquid in the electronics area of the system may damage the system and void the warranty Before using any cleaning or deco...

Page 24: ...the unit is plugged into for a tripped circuit breaker or blown fuse Reset or replace the breaker or fuse as required Power indicator has failed If the time and temperature displays are lit and the r...

Page 25: ...s going off Silence the buzzer by pressing the button Liquid level is too high or too low Check the indicator lights on the right side of the control panel If either level indicator is on add or remov...

Page 26: ...ke screen is clogged Drain the tank as instructed in the section Maintaining your SCA Clean the intake screen with a toothbrush until debris is removed from the holes ALWAYS WEAR PROTECTIVE GLOVES AND...

Page 27: ...aterWorks is a more efficient cleaning concentrate Liquid Level indicators did not turn off when liquid was added removed from the tank Sensors or Indicators have failed Contact technical support Syst...

Page 28: ...C 85 C Operating Environment Ranges Temperature 5 C 40 C Humidity 0 80 RH Altitude 0 M 2000 M Temperature Control Accuracy 2 C Pump Max Flow Rate 10 GPM 38 LPM Temperature Display Digital LED Readout...

Page 29: ...der warranty or covered by a maintenance contract contact the Authorized Reseller from whom the unit was purchased Otherwise to receive technical support visit www SupportRemoval com Resources and pro...

Reviews: