IMPORTANT - If, within one minute 

after the green light has come on, the 

motor fan does not begin running, shut 

the unit off, unplug the cord and contact 

PackTite™ at [email protected].  

(This is an indication that the unit may 

have been damaged during shipping).

8.  When the green light goes off, unplug 

the cord from the outlet, unzip the flap 

and wait 5 minutes before removing 

items.

 

OPERATING INSTRUCTIONS

 

Scientific studies report the lethal 

temperature for bed bugs as 113º F 

(adults) and 120º F (all life stages). 

Monitor the 

temperature of the 

items being treated to 

insure that the internal 

temperature of all 

items being treated 

reaches 120º F and 

holds that temperature 

for 60 minutes.

 

Luggage: 

 Luggage 

contents typically reach 

lethal temperatures within the standard 

4-hour treatment period.  Place the 

thermometer probe in the center of the 

packed suitcase.   You may wish to treat 

for more than 4 hours to insure that 

the contents are held at 120º F for 60 

minutes. 

Personal items:

  

Heating of personal 

items in PackTite™ 

varies greatly depending 

on the number and 

types of items you are 

treating. Treatment 

times will range from 

1 hour to 4 hours. For 

maximum effectiveness, 

monitor the temperature by placing the 

thermometer probe in the center of the 

item to be treated (for example: in the 

TEMPERATURE MONITORING

 

IMPORTANT: 

Summary of Contents for PackTite

Page 1: ...TRUCTIONS Eliminates stowaway bed bugs from your luggage Treats personal items for bed bugs Patent Pending heating technology safely eliminates all stages of bed bugs Please read these instructions carefully before using this device ...

Page 2: ...onal items onto the support rack 2 IMPORTANT Do NOT place any items on the terminal 2 inches on either side of the rack This is a ventilation area and must be kept clear Blocking this vent area will cause a safety shutdown and the unit will need to be shipped to PackTite for repair AT THE BUYER S EXPENSE 3 Make sure no part of the luggage or any other materials dangle below the support rack or com...

Page 3: ... to insure that the internal temperature of all items being treated reaches 120º F and holds that temperature for 60 minutes Luggage Luggage contents typically reach lethal temperatures within the standard 4 hour treatment period Place the thermometer probe in the center of the packed suitcase You may wish to treat for more than 4 hours to insure that the contents are held at 120º F for 60 minutes...

Page 4: ... temperature inside the PackTite you must turn the switch to the OUT setting DO NOT PLACE ITEMS BEYOND THE MARKERS ON EITHER SIDE OF THE RACK Blocking this vent area may cause a safety shutdown that will require sending the unit back for repair AT THE BUYER S EXPENSE The following items should be removed from luggage and should NOT be treated in PackTite MEDICATIONS LIQUIDS FOOD PackTite is NOT re...

Page 5: ...ith water Never locate unit where it may fall into a bathtub or other water container 9 DO NOT run cord under carpeting DO NOT cover cord with throw rugs runners or similar coverings Arrange cord and device away from traffic areas and where it will not be tripped over 10 To unplug the device first turn attached electronic timer to off then remove plug from outlet 11 DO NOT insert or allow foreign obje...

Page 6: ...remove all contents from the device Allow the device to cool for a few minutes plug it back in and resume normal operation 21 If your device fails to operate a Make sure your circuit breaker or fuse is working properly b Make sure the device is plugged in and that the outlet is working properly c Check for and remove any obstructions close to the heating unit d DO NOT ATTEMPT TO OPEN OR REPAIR THE...

Page 7: ...ious near the motor heating elements and fan of the heating unit NEVER use abrasive or flammable solvents to clean any part of PackTite After cleaning be sure to completely dry PackTite with a cloth or towel Store PackTite in its original carton in a cool dry location CLEANING MAINTENANCE SPECIFICATIONS Specifications for heating unit in device Voltage 120V 60Hz Current Maximum continuous draw 5 0 A...

Page 8: ...evice is required or if you have any questions please contact us at service PackTite com SERVICE SUPPORT Patent Pending EPA Est No 85055 PackTite is assembled in the United States from components made in China Taiwan and the U S A ...

Reviews: