background image

center of a pile of linens, inside a purse, 

backpack or shoe).

For all items, it is recommended that 

treatment be terminated (regardless of 

the treatment time) if the temperature 

reaches 150º F.  

The thermometer provided is a standard 

Indoor/Outdoor thermometer, designed 

to read both an IN temperature and an 

OUT temperature.   Place the probe 

inside the PackTite™ in the center of 

the item(s)  being treated.  The OUT 

reading will give the temperature inside 

the  treated item(s).  Your thermometer 

may have a small switch that can be 

toggled to read either the OUT or the 

IN temperature.  If your  thermometer 

has this switch,  you must turn it to 

the OUT setting. In order to read the 

temperature inside the PackTite™, 

you must turn the switch to the OUT 

setting.

DO NOT PLACE ITEMS BEYOND 

THE MARKERS ON EITHER SIDE 

OF THE RACK.  Blocking this vent 

area may cause a safety shutdown that 

will require sending the unit back for 

repair AT THE BUYER’S EXPENSE.

The following items should be 

removed from luggage and should 

NOT be treated in PackTite™:  

MEDICATIONS, LIQUIDS, FOOD.

PackTite™ is NOT recommended for 

treating electronic devices, including 

COMPUTERS, IPODS, MP3 

PLAYERS, CAMERAS.

Always operate PackTite™ in ambient 

temperature conditions of at least  

70º F.  Colder ambient temperatures 

may prevent the device and its contents 

from reaching temperatures necessary 

for eliminating all life stages of bed 

bugs.

Take care not to overfill the PackTite™.  

Place items so they do not touch the 

outer sides, power cord, top flap or 

zipper.

IMPORTANT

TEMPERATURE MONITORING

Summary of Contents for PackTite

Page 1: ...TRUCTIONS Eliminates stowaway bed bugs from your luggage Treats personal items for bed bugs Patent Pending heating technology safely eliminates all stages of bed bugs Please read these instructions carefully before using this device ...

Page 2: ...onal items onto the support rack 2 IMPORTANT Do NOT place any items on the terminal 2 inches on either side of the rack This is a ventilation area and must be kept clear Blocking this vent area will cause a safety shutdown and the unit will need to be shipped to PackTite for repair AT THE BUYER S EXPENSE 3 Make sure no part of the luggage or any other materials dangle below the support rack or com...

Page 3: ... to insure that the internal temperature of all items being treated reaches 120º F and holds that temperature for 60 minutes Luggage Luggage contents typically reach lethal temperatures within the standard 4 hour treatment period Place the thermometer probe in the center of the packed suitcase You may wish to treat for more than 4 hours to insure that the contents are held at 120º F for 60 minutes...

Page 4: ... temperature inside the PackTite you must turn the switch to the OUT setting DO NOT PLACE ITEMS BEYOND THE MARKERS ON EITHER SIDE OF THE RACK Blocking this vent area may cause a safety shutdown that will require sending the unit back for repair AT THE BUYER S EXPENSE The following items should be removed from luggage and should NOT be treated in PackTite MEDICATIONS LIQUIDS FOOD PackTite is NOT re...

Page 5: ...ith water Never locate unit where it may fall into a bathtub or other water container 9 DO NOT run cord under carpeting DO NOT cover cord with throw rugs runners or similar coverings Arrange cord and device away from traffic areas and where it will not be tripped over 10 To unplug the device first turn attached electronic timer to off then remove plug from outlet 11 DO NOT insert or allow foreign obje...

Page 6: ...remove all contents from the device Allow the device to cool for a few minutes plug it back in and resume normal operation 21 If your device fails to operate a Make sure your circuit breaker or fuse is working properly b Make sure the device is plugged in and that the outlet is working properly c Check for and remove any obstructions close to the heating unit d DO NOT ATTEMPT TO OPEN OR REPAIR THE...

Page 7: ...ious near the motor heating elements and fan of the heating unit NEVER use abrasive or flammable solvents to clean any part of PackTite After cleaning be sure to completely dry PackTite with a cloth or towel Store PackTite in its original carton in a cool dry location CLEANING MAINTENANCE SPECIFICATIONS Specifications for heating unit in device Voltage 120V 60Hz Current Maximum continuous draw 5 0 A...

Page 8: ...evice is required or if you have any questions please contact us at service PackTite com SERVICE SUPPORT Patent Pending EPA Est No 85055 PackTite is assembled in the United States from components made in China Taiwan and the U S A ...

Reviews: