23/78
06/02/2008
1.00
Placing the agitator on VM/DX
Remark
The agitator blades and the motor are delivered separately.
How to place it?
Take the following steps to place the agitator :
Step
Action
1
Open the tank and put the agitator blades (6) inside.
2
Put the shaft trough the hole in the lid (1).
3
Slip the rubber agitator shaft shield (2) over the end of the agitator
shaft. Fit it onto the lid.
4
Put the distance ring (3) on the lid.
5
Push the agitator bushing over the motor (4) output shaft, align the
holes in both shafts and insert the stainless steel elastic pin.
6
For tanks with 1 lid: in the motor terminal box a float switch is fitted
which cuts the power supply to the motor the moment the lid is
opened. To have this function, the agitator motor positioning has to be
choosen accordingly.
Test this function during commissioning
7
Secure the motor to the lid with 4 bolts and spring washers (5): the
bolts on the inside of the distance ring.
4
3
2
1
5
6