V. Venting Instruction

side wall cap

w/gravity damper

cabinet

soffit or crawl space

side wall cap

w/gravity damper

roof pitch w/

flashing & cap

WARNING FIRE HAZARD

Some Ducting Options

NEVER exhaust air or terminate duct work into spaces between walls, 
crawl spaces, ceiling, attics or garages. All exhaust must be ducted to

the outside. Use metal ductwork only.
Fasten all connections with sheet metal screws and tape all joints
with 

certified Silver Tape or Duct Tape. 

5 .

5.

五.安裝排風管

用重力阻尼器

加蓋於側牆面

櫥櫃

依梁柱底面或櫥櫃空間爬行

用重力阻尼器

加蓋於側牆面

屋面坡度可以用遮雨罩或其他遮罩加蓋

櫥櫃安裝注意事項:

安裝之風管

牆壁

櫥櫃空間

天花板或車庫與閣樓之間的空間都要

有所保留

風管只能使用金屬材質

安裝之連接處的金屬螺絲要鎖緊

接頭處要用有認證的銀膠帶或風管

膠帶貼緊

風管安裝選項:

Rear Ducting

背面排風

Summary of Contents for PR830AS

Page 1: ...XP022396 1 PR830AS PR836AS XP022396 1 Use Care and lnstallation Guide Model PR830AS PR836AS Model number Serial Number...

Page 2: ......

Page 3: ...1 II Parts Instructions 2 III Installation Guidelines 3 IV Installation Procedures 4 V Venting Instruction 5 VI Installation Air outlet 6 7 VII Operating Instructions 8 VIII Replacing Light Bulb 9 IX...

Page 4: ...rt A Product Functions 1 3 speed options 2 Light has varying degrees of brightness Bright Dim and Off B Specification Chart Net weight Pound Models Measurement inches Maximum Voltage Exhaust Pipe Diam...

Page 5: ...crews M6 x 2 wood screws 3 16 x 1 2 screws Wall bracket 3 4 4 4 4 1 2 4 A F C B D E H G Halogen light Suction Cup 4 5 3 8 10 11 12 13 7 1 6 9 2 PR830AS PR836AS 4 5 3 8 10 11 12 13 7 1 6 9 2 6 Shell 3...

Page 6: ...l in the oil tub from spilling over To ensure that the hood is leveled when installing it can be measured by the hook mark for the left and right side and the screws fixed securely onto the wall to en...

Page 7: ...s are framed 4 Remove baffle filters from hood Also remove side panels from hood using a Phillips screwdriver to remove each of the screws And then remove the grease tray 5 Use 4 wooden screws to secu...

Page 8: ...p WARNING FIRE HAZARD Some Ducting Options NEVER exhaust air or terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use metal...

Page 9: ...gular collar on top of rectangular transition adapter Secure rectangular adapter and rectangular collar to hood body using the previously removed screws from step 1 3 1 4 x10 Rectangular Vertical Duct...

Page 10: ...the rectangular opening on top of hood from step 3 Secure rectangular transition adapter and cover plate to hood body using the previously removed screws from step 1 3 Using a Philips head screwdrive...

Page 11: ...or bright light Rotate knob to change speed levels 1 for low speed 2 for medium speed and 3 for high speed 1 Blower on off speed selection 2 Lights Dim Bright Off 1 1 2 3 1 2 2 1 Blower on off speed s...

Page 12: ...ot to handle Please double check to make sure the power supply to the range hood is shut off and the light bulb is cool before removing it Remove the Halogen bulb by turning it counter clockwise to re...

Page 13: ...ange hood surface shinier 5 Please do not use cleaning solutions that have bleach as an ingredient 1 2 3 1 2 3 4 5 1 2 3 IX Surface Maintenance 1 2 3 4 30 5 1 Always disconnect from power supply befor...

Page 14: ...blower wheel 3 The hood is not secured in place 3 Check the installation of the hood The motor is working but the lights are not 1 Defective halogen bulb 1 Change the halogen bulb 2 The light bulb is...

Reviews: