SECTION 4
OPERATION
34
4.2.2 UPC FRONT PANEL (cont’d)
13)
ENTER
(KEY)
Is used to enter numeric values then move the cursor to the next
data field.
14)
PROGRAM
(KEY)
When pressed from any meter display causes PROGRAM
OPERATE MODE to be active.
15)
EDIT
(KEY)
When pressed from the PROGRAM display causes PROGRAM
EDIT MODE to be active. Pressing the
EDIT
key again causes the
TRANSIENT display to be active.
16)
STORE
(KEY)
After editing, the
STORE
key is used to save new values.
17)
DISPLAY
(KEY)
Is used to cycle through the meter displays. If a display other than a
meter display is active it will abort edit functions and return to the V/I
METER display.
18)
EXECUTE
(KEY)
In MANUAL MODE, causes the output to change to new values.
In PROGRAM OPERATE MODE, causes a new program to be
executed.
In PROGRAM EDIT MODE and in the PROGRAM display, causes
the program to be saved and executed.
In SETUP MODE is used to change the setup of the UPC.
19)
ARROW
(
︿
or
﹀
)
KEYS
When in MANUAL MODE, pressing an ARROW key causes the
selected parameters to slew up or down.
20)
TRANS
(KEY)
When in PROGRAM OPERATE MODE and a transient is stored,
pressing this key causes the transient to start or stop. When the
LED is lit this indicates a transient is in progress.
21)
OUTPUT ENABLE
(KEY)
Causes the output relay ENABLE to toggle on and off. When the
LED is lit this indicates output enable is active. Activating output
power of an AMX or ASX power source also requires that the
Output Power switch on the front panel be in the ON/AUTO position.
Summary of Contents for UPC-3
Page 2: ......
Page 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Page 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 3 Figure 1 3b UPC 3 Figure 1 3c UPC 1 ...
Page 43: ...SECTION 4 OPERATION 31 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Page 74: ...SECTION 4 OPERATION 62 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...
Page 134: ...NOTES 122 NOTES ...