SECTION 10 SERIAL REMOTE INTERFACE
115
SECTION 10
RS-232 SERIAL REMOTE INTERFACE OPTION
10
RS-232 SERIAL REMOTE INTERFACE OPTION
This section describes using the optional RS-232 (Serial) REMOTE interface of the UPC. This section is
intended to be used in conjunction with section 5 of this Operation Manual.
10.1 GENERAL
The RS-232 REMOTE interface of the UPC is the standard communication port for the UPC-3 and UPC-
1. See paragraph 10.3 for setup information. An optional GPIB/IEEE-488 parallel communication port
may be installed in place of the serial port. Check the connector label at the rear of the unit to determine
which interface is installed.
10.2 SERIAL PORT SPECIFICATIONS
The RS-232 Remote Interface of the UPC is compatible with the ANSI/IEEE-488.2, SCPI and RS-232C
standards. It loosely adheres to the RS-232C standard as some interfacing requirements of that
standard are not necessary.
This Remote Interface of the UPC has the following communication characteristics:
1. Selectable
BAUD RATES
of:
38400 BAUD
19200 BAUD (default)
9600 BAUD
4800 BAUD
2400 BAUD
1200 BAUD
300 BAUD
2. Selectable
PARITY
of ODD, EVEN or NONE (default).
3. Selectable
EOS
(End Of String) Terminator CR, LF or CR/LF (default): Sets the EOS sent from
the UPC. The UPC accepts any of the above combinations when receiving.
4.
8 Data bits, 1 Start bit, 1 Stop bit.
5.
HANDSHAKE: None.
The Serial Remote interface of the UPC has no Handshake. This is a simple 2 wire interface.
6.
Operation is HALF-DUPLEX (per IEEE-488.2).
Refer to section 10.6 below for Pinouts and Signal names.
Summary of Contents for UPC-3
Page 2: ......
Page 12: ...SECTION 1 GENERAL viii THIS PAGE INTENTIONALLY BLANK ...
Page 17: ...SECTION 1 GENERAL 5 PACIFIC Figure 1 3a SCU UPC 3 Figure 1 3b UPC 3 Figure 1 3c UPC 1 ...
Page 43: ...SECTION 4 OPERATION 31 PA CIFIC FIGURE 4 1 POWER SOURCE FRONT PANEL ...
Page 74: ...SECTION 4 OPERATION 62 90 0 100 0 85 95 100 90 FIGURE 4 6 2 1 EDITED WAVEFORM ...
Page 134: ...NOTES 122 NOTES ...