SECTION 2 SPECIFICATIONS
14
2.1.1 INPUT POWER REQUIREMENTS
(cont.)
MODEL 3120-AMX
INPUT VOLTAGE AND INPUT CURRENT
The Model 3120-AMX three phase input voltages, required input currents at full rated load and
recommended service input currents are stated as below.
INPUT
CURRENT
(360-440 Hz optional)
INPUT
CURRENT
SERVICE
RECOMMENDED
1) 208
VAC
∆
±10%, 47-63 Hz
58 A
rms
80
A
2) 220
VAC
∆
±10%, 47-63 Hz
54 A
rms
80
A
3) 230
VAC
∆
±10%, 47-63 Hz
52 A
rms
80
A
4) 240
VAC
∆
±10%, 47-63 Hz
50 A
rms
80
A
5) 220/380 VAC ±10%, 47-63 Hz
32 A
rms
40
A
6) 230/400 VAC ±10%, 47-63 Hz
30 A
rms
40
A
7) 240/416 VAC ±10%, 47-63 Hz
30 A
rms
40
A
( cost option )
8) 277/480 VAC ±10%, 47-63 Hz
28 A
rms
40
A
Summary of Contents for AMX Series