SECTION 2 SPECIFICATIONS
8
2.1.1 INPUT POWER REQUIREMENTS (cont.)
MODEL 108-AMX
INPUT VOLTAGE AND INPUT CURRENT
The Model 108-AMX single phase input voltages, required input currents at full rated load and
recommended service input currents are stated as below.
MODEL 112-AMX
INPUT VOLTAGE AND INPUT CURRENT
The Model 112-AMX single phase input voltages, required input currents at full rated load and
recommended service input currents are stated as below.
INPUT
VOLTAGE
(360-440 Hz optional)
INPUT
CURRENT
SERVICE
RECOMMENDED
1)
100 VAC ±10%, 47-63 Hz
17 A
rms
25
A
2)
110 VAC ±10%, 47-63 Hz
16 A
rms
25
A
3)
120 VAC ±10%, 47-63 Hz
15 A
rms
25
A
4)
200 VAC ±10%, 47-63 Hz
9 A
rms
25
A
5)
208 VAC ±10%, 47-63 Hz
9 A
rms
25
A
6)
220 VAC ±10%, 47-63 Hz
8 A
rms
15
A
7)
230 VAC ±10%, 47-63 Hz
8 A
rms
15
A
8)
240 VAC ±10%, 47-63 Hz
8 A
rms
15
A
INPUT VOLTAGE
INPUT
CURRENT
SERVICE
RECOMMENDED
1)
100 VAC ±10%, 47-63 Hz
21 A
rms
25
A
2)
110 VAC ±10%, 47-63 Hz
19 A
rms
25
A
3)
120 VAC ±10%, 47-63 Hz
18 A
rms
25
A
4)
200 VAC ±10%, 47-63 Hz
11 A
rms
15
A
5)
208 VAC ±10%, 47-63 Hz
11 A
rms
15
A
6)
220 VAC ±10%, 47-63 Hz
10 A
rms
15
A
7)
230 VAC ±10%, 47-63 Hz
9 A
rms
15
A
8)
240 VAC ±10%, 47-63 Hz
9 A
rms
15
A