![Pacific Power Source 105LMX Operation Manual Download Page 447](http://html.mh-extra.com/html/pacific-power-source/105lmx/105lmx_operation-manual_746366447.webp)
LMX SERIES™ OPERATION MANUAL
SECTION 12: Warnings & Error Messages
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 447 of 463
Error Source
Code
Category Error Message
Possible Cause
Resolution
completing front panel
firmware update
Front panel
337
Internal
Error
Missed node.
An inconsistency was
detected in the power
source's internal
communication network.
Try recycling power. If
error persists, contact
customer service
Front panel
338
Error
One or more enhanced
controllers did not get
enabled.
Failed to enable one or
more controllers
Try recycling power. If
error persists, contact
customer service
Front panel
341
Internal
Error
Firmware version
mismatch. Power stage
version is older than
expected.
Firmware Error. Power
stage firmware version is
older than expected
Contact customer service
Front panel
342
Internal
Error
Firmware version
mismatch. Front panel
version is older than
expected.
Firmware Error. Front
panel firmware version is
older than expected
Contact customer service
Front panel
343
Error
Mismatch between
hardware revisions of
units in parallel.
Error during discovery.
Not all paralleled units
are of same hardware
revision
Contact customer service
Front panel
344
Error
Power stage firmware
update failed.
Run
SYSTem:FW:INT:UPDATE:
STAT? for more
information.
Run unit discovery to
recover
Front panel
345
Error
Firmware update was
interrupted.
Recovery is needed.
Run unit discovery to
recover
Front panel
346
Error
GPIB hardware not found
in this unit.
Configuration Error. GPIB
Interface option not
found
Check model type tag for
installed options
Front panel
347
Error
GPIB hardware detected
Configuration Error. GPIB
Interface found but not
configured
Check model type tag for
installed options
Front panel
348
Error
IO hardware not found in
this unit.
Configuration Error. Aux
I/O hardware missing
Check model type tag for
installed options
Front panel
349
Error
IO hardware detected
Configuration Error. Aux
I/O hardware found but
not configured
Check model type tag for
installed options
Front panel
350
Internal
Error
Analog inputs cannot be
read.
Configuration Error. No
data received from
analog inputs
Check connections to
AUX I/O connector and
pin assignments
Front panel
351
Error
Transformer hardware
detected.
Unit model mismatch.
Front panel
352
Error
Ambient temperature
exceeded maximum limit.
Front panel
353
Error
Enhanced controller
hardware not found in
this unit.
Front panel
354
Error
Enhanced controller
hardware detected.
Unit model mismatch.
Front panel
355
Error
Mismatch between
models of units in
parallel.
Front panel
356
Error
Unit model mismatch.
Front panel
357
Internal
Error
Digital inputs cannot be
read.