![Pacific Power Source 105LMX Operation Manual Download Page 211](http://html.mh-extra.com/html/pacific-power-source/105lmx/105lmx_operation-manual_746366211.webp)
LMX SERIES™ OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
LMX Series Power Source Operation Manual
Page 211 of 463
Query Format
MEASure:CURRent:AC#?"
Description
Returns the measured RMS current for the selected phase #. If no
phase number is specified, returns the reading for all phases. This
command is equivalent to “MEASure:CURRent[:ACDC]#?” and is
provided for backward compatibility with the UPC controllers.
Returned Data Format
<nr2>
Query Example
MEAS:CURR:AC1?
21.1587
8.4.4
Power Measurement Commands
Query Format
MEASure:POWer#?
Description
Returns the true power for the selected phase # in kW. If no phase
number is specified, returns the reading for the last selected phase.
Returned Data Format
<nr2>
Query Example
MEAS:POWer1?
4.4203
Query Format
MEASure:KVA#?
Description
Returns the true apparent for the selected phase # in kVA. If no
phase number is specified, returns the reading for the last selected
phase.
Returned Data Format
<nr2>
Query Example
MEAS:KVA1?
4.8665
Query Format
MEASure:PF#?
Description
Returns the true apparent for the selected phase # in kVA. If no
phase number is specified, returns the reading for the last selected
phase.
Returned Data Format
<nr2>
Query Example
MEAS:PF1?
0.9083
8.4.5
KWh Measurement Commands
Query Format
MEASure:KWHour#?
Description
Returns the accumulated energy measurement for the selected
phase # in kWh. If no phase number is specified, returns the total
summed KWh for all phases.
Returned Data Format
<nr2>
Query Example
MEASure:KWHour?
12.4203