LMX Series Power Source Operation Manual
Page 228 of 463
8.6
Program Commands
Program commands allow management and programming of stored program segments for
steady state. These commands are grouped by the following subsystems.
•
Program Control Commands
•
Execution Commands
•
Memory Management Commands
The Program commands are similar to those found on the Pacific Power UPC controllers
used for other PPS AC power source models.
8.6.1
Program Control Commands
The following commands allow recall of stored programs and transient segments. Programs
are selected and recalled using their memory location reference ranging from 1 through 99.
Program location zero (0) is reserved for the Manual Mode setup. Optionally, a memory
source may be specified. If none is provided, INTERNAL memory is used as a default.
Command Syntax
PROGram:NAME [<nr1>,] [<cr>,] <cr>
Description
This command selects program <nr1> for execution deletion or
copying.
Parameters
Option: PROGRAM, NUMBER [,<cr>} or [,<nr1>] - 0 through 99
Option: MEMORY [,<cr>] – Available are: INTERNAL | RAM | USB
Parameter list define string <cr>,<cr>,….,<cr>
Parameter Format
<nr1> [,<cr>]
Example
PROG:NAME 4, USB
Query Format
PROGram:NAME?
Description
The query format of this command returns the value of last program
selected. Returned value range is 0 through 99.
Returned Data Format
<nr1>
Query Example
PROG:NAME?
4