Setup & Operation
Model Two HDCD
®
User’s Manual
Rev. C - January 2002
justable parameters (see pages 59 and 60 in the Reference Section to set OVER indication
parameters). Meter brightness is set in the Front Panel Display Menu (SETUP/MORE.../
SYSTEM/PANEL).
Meter Source
Meter signal sources are selected in the Operating Menu. The source options are: OUT_1
(Digital Output 1), OUT_2 (Digital Output 2), DIG_IN (Digital Input 1), except AD+DD44
and AD+DD48 Operating Modes also have DIG_IN2 (Digital Input 2). 88.2 kHz, 96 kHz,
176.4 kHz and 192 kHz Operating Modes have OUTPUT and DIG_IN only.
Meter Display Mode
Meter display mode options are selected in the Operating Menu. The options are NORMAL,
FINE, and BITS.
NORMAL Shows the full dynamic range of the metered signal with a bar displaying aver-
age signal level and a separate pip, which normally floats above the bar, indicating peak
level. A standard peak reading bar mode is also available by selecting PEAKBAR in the
Meter Display Menu (SETUP/MORE.../METER).
Off
=
No Signal Present
Green
=
-
∞
to -11 dB Signal
Yellow
=
-10 dB to -1 dB Signal
Amber
=
0 dB Signal
Red
=
Over Signal
FINE
Displays average signal level at .2 dB per segment resolution, with the selected
meter operating reference level indicated by the green to yellow LED transition point. Two
adjacent LED segments are lit in fine mode, therefore exact reference level is indicated
when both one green and one yellow segment are lit. Two lit green segments mean the
level is low, and two lit yellow segments mean the level is high. The meter operating
reference level is set in the Meter Setup Menu (SETUP/MORE.../METER).
BITS
Displays bit activity of the digital audio word, indicating active word length. The
MSB and bits 16, 20, and 24 are labeled on the bargraph.
Peak Level Hold
Peak level hold modes are selectable in the Meter Setup Menu (SETUP/MORE.../METER).
Peak level hold may be set to NONE, SHORT (1.5 seconds), LONG (4 seconds), or HOLD
(until reset). The Meter Reset button clears held peak indications.