6
VENT SYSTEM
Before starting installation of vent kits, the installer should read these
instructions to ensure that the proper vent system has been selected
for the installation.
Vent systems approved for use with the Oxford Direct Vent Heater are
shown in Figure 4. Approved vent systems components are labelled
for identification.
NO OTHER VENTING SYSTEMS OR COMPO-
NENTS MAY BE USED.
Connections between each vent system component must be tightly
joined and sealed, and secured with sheet metal screws at each joint.
Consult your local Building Codes before beginning the installation.
CAUTION: UNDER NO CONDITION SHOULD COMBUSTIBLE
MATERIAL BE CLOSER THAN 1-INCH FROM THE VERTICAL
AND HORIZONTAL SECTIONS OF THIS VENT SYSTEM.
INSTALLATION PRECAUTIONS
The Oxford Heater installation and venting must conform with
local codes or, in the absence of local codes, with the current
Canadian Installation Code, CAN/CGA-B149 (in Canada) or the
current National Fuel Gas Code, ANSI Z223.1 (in the USA). Only
qualified (licensed or trained) personnel should install this prod-
uct.
The Oxford may be converted to a Vented Room Heater with the
optional "B-Vent Adapter". Refer to the installation instructions
that are supplied with the kit for proper venting requirements.
Only qualified (licensed or trained) personnel should install this
product.
Fig # 4
PART DESCRIPTION
PART #
MFSD.RVT
RISER VENT TERMINAL
MFSD.STRT 18
18" STARTER PIPE
MFSD.THIMB
WALL THIMBLE SPACER
MFSD.1551_ _
TRIM COLLAR (SQUARE)
MFSD.ELB 45
45° COAXIAL ELBOW
MFSD.ELB 90
90° COAXIAL ELBOW (2)
MFSD.WSS
WALL SUPPORT SPACER
MFSD.CP24
24" COAXIAL PIPE
MFSD.CP48
48" COAXIAL PIPE
MFSD.BVADPT
B-VENT ADAPTER
Specify Colour