Pacific energy The Oxford Installation And Operating Instructions Manual Download Page 18

18

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: If you do not follow these instructions exactly, a fire
or explosion may result causing property damage, personal
injury or loss of life.

A. This appliance has a pilot which must be lighted by hand. When lighting the pilot,

follow these instructions exactly.

B. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell

next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS:

- Do not try to light any appliance.
- Do not touch any electric switch; do not use any phone in your building.
- Immediately call your gas supplier from a neighbour's phone. Follow the gas
supplier's instructions.
- If you cannot reach your gas supplier, call the fire department.

C. Use only your hand to push in or turn the gas control knob. Never use tools. If the

knob will not push in or turn by hand, don't try to repair it, call a qualified service
technician. Force or attempted repair may result in a fire or explosion.

D. Do not use this appliance if any part has been under water. Immediately call a

qualified service technician to inspect the appliance & to replace any part of the
control system & any gas control which has been under water.

LIGHTING INSTRUCTIONS

1. STOP! Read the safety information above on this label.
2. Set wall thermostat to lowest setting, if applicable.
3. Turn off all electric power to the appliance.
4. Partially depress and turn gas valve knob clockwise 

past "Pilot" to "Off" position.

Note: Knob cannot be turned from "Pilot" to "Off" unless knob

is pushed in slightly. Do not force.

5. Wait five (5) minutes to clear out any gas. Then smell for

gas, including near the floor. If you still smell gas, STOP!
Follow "B" in the safety information above on this label. If
you don't smell gas, go to the next step.

6. Turn gas valve knob back to "Pilot" position.
7. Depress gas valve knob fully and hold while you ignite pilot

with the push button igniter. Once the pilot ignites, con-
tinue depressing knob for approximately 5 seconds. If pilot does not stay lit,
repeat steps 4 through 7, allowing a longer period before releasing gas valve
knob.
- If gas valve knob does not pop up when released, stop and immediately call your
service technician or gas supplier.
- If the pilot will not stay lit after several tries, turn the gas valve knob to "Off" and
call your service technician or gas supplier.

8. Turn gas valve knob counter-clockwise 

 to "On" position.

9. Turn HI-LO burner control knob to desired setting.
10. Turn on all electric power to the appliance.
11. Set thermostat to desired setting, if applicable.

Note: Sufficient time must be allowed for air to escape from lines if the unit is
being lit for the first time.

TO TURN OFF GAS TO APPLIANCE

1. Set wall thermostat to lowest setting, if applicable.
2. Turn off all electric power to the appliance if service is to be performed.
3. Push in gas control knob slightly and turn clockwise 

 to "Off". Do not force.

Keep burner and control compartment clean. See installation and operating
instructions accompanying the appliance.

GAS

VALVE

GAS VALVE SHOWN
IN "OFF" POSITION

f i r e - p a r t s . c o m

Summary of Contents for The Oxford

Page 1: ...s supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier IMPORTAN...

Page 2: ...ALL INSTALLATION 7 CORNER INSTALLATION 8 BASEMENT INSTALLATION 10 ATTACHMENT TO FLOOR 10 ALTERNATE VENTING 11 VENT TERMINAL INSTALLATION 15 GLASS FRONT REMOVAL 16 LOG SET 17 GLOWING EMBERS 17 FIRST FI...

Page 3: ...ved cracked or broken Replacement of glass should be done by a licensed or qualified service person Do not strike or otherwise impact the glass in anyway that may cause ittobreak Iftheglassbecomescrac...

Page 4: ...ttom of the control assembly 5 Connect burner switch wires to the back of the rocker switch 6 Insert valve knob extensions through the control panel and onto their corresponding valve knobs Fig 2 7 In...

Page 5: ...ired Alcove sidewall to appliance clearance is listed at 4 3 4 A 10 clearance is recommended to center the appliance in a 48 minimum wide Alcove Sidewall to Appliance 3 in 76 mm Rearwall to Appliance...

Page 6: ...ON PRECAUTIONS The Oxford Heater installation and venting must conform with local codes or in the absence of local codes with the current Canadian Installation Code CAN CGA B149 in Canada or the curre...

Page 7: ...ll thickness and or rear clearance of the stove Measure the wall thickness from the finished trim collar surface to the exterior mounting surface for the vent terminal Add 1 4 inch plus rear clearance...

Page 8: ...6 Attach the coaxial 45 elbow LB 45 to the unit Slide the 5 inch inner elbow pipe 1 inch over top of the collar and secure with three sheet metal screws Seal the joint with high temperature silicone N...

Page 9: ...9 Fig 8 MAXIMUM MAXIMUM MAXIMUM MAXIMUM MAXIMUM fire parts com...

Page 10: ...gh temperature silicone and secured with screws 3 Continue adding vent components per the pre planned system configuration Support spacer must be used for each 6 feet of vertical and horizontal run Th...

Page 11: ...are main tained Follow vent pipe manufacturer s instructions for assembly and installation ALTERNATE VENTING SIMPSON DURA VENT DIRECT VENT GS SYSTEM CAUTION UNDER NO CONDITION SHOULD COMBUSTIBLE MATER...

Page 12: ...nimum 6 vertical rise is required for a wall termination see Fig 9a For horizontal runs greater than 6 increase vertical rise equally Horizontal run must not exceed 8 feet Any combination of rise grea...

Page 13: ...to 30 feet is permited with no horizontal run If horizontal run is required ensure that vertical rise is equal or greater than run Horizontal run must not exceed 8 feet Combined vent length must not e...

Page 14: ...on Cap Vertical 991 Low Profile Termination Cap Vertical 980 Extended Vertical Termination Cap Vertical 930 Horizontal Square Termination Cap 984 Snorkel Termination Cap 36 981 Snorkel Termination Cap...

Page 15: ...rom the center line of the terminal 18 inches 46 cm minimum E clearance to unventilated soffit 18 inches 46 cm minimum F clearance to outside corner 8 inches 20 cm minimum G clearance to inside corner...

Page 16: ...damage Handle enamelled parts carefully to avoid chipping Window Frame Removal 1 Remove two wing nuts located at the base of the window frame 2 Grasp the sides of the frame and swing the bottom out t...

Page 17: ...y are very fragile Note Improper placement of logs may cause soot ing on internal parts and glass Step 2 Left Log Placement log 2 Step 3 Right Log Placement log 3 Step 4 Middle Twig Placement log 4 St...

Page 18: ...n gas valve knob clockwise past Pilot to Off position Note Knob cannot be turned from Pilot to Off unless knob is pushed in slightly Do not force 5 Wait five 5 minutes to clear out any gas Then smell...

Page 19: ...a comfortable temperature Turn the HI LO burner control knob to a desired setting As heat is required the Oxford heater will turn on or off automatically as needed Extend Shutdown To shutdown the appl...

Page 20: ...SC THERMO OPTIONAL WALL SWITCH OPTIONAL REMOTE CONTROL GASC REMOTE ROCKER SWITCH THERMOPILE GAS VALVE Fig 18 Recommended Thermostat Wire Size Wire Size Max Length 14 ga 100 ft 16 ga 60 ft 18 ga 40 ft...

Page 21: ...AL BASE OXFD 2546 16 FRONT OVERLAY OXFD 2599_ _ 17 WINDOW FRAME OXFD 2518 18 GLASS GASKET KIT MFSD 50671 19 REPLACEMENT GLASS 5034 1 20 FRONT FIREBOX PANEL 5097 661 21 LEFT FIREBOX PANEL 5097 662 22 R...

Page 22: ...22 NOTES fire parts com...

Page 23: ...01A in the U S A Cet appareil diot tre install conformem nt aux exigences de la norme CAN CSA Z240 MH en vigueur de l ACNOR Installations de gaz dans les Constructions Mobiles This appliance is only f...

Page 24: ...24 Pacific Energy Fireplace Products Ltd PO Box 1060 Duncan B C V9L 3Y2 Phone 250 748 1184 Web site http www pacificenergy net Printed in Canada fire parts com...

Reviews: