Pacific energy The Oxford Installation And Operating Instructions Manual Download Page 23

23

RATING LABEL

FOR USE WITH/

NATURAL GAS/

LP GAS/

EN CASE D’EMPLOI AVEC:

DU GAZ NATUREL DU GAZ LP

Minimum supply pressure / Pression minimum d’alimentation:

5.0 in. wc / 5.0 po. c.e.

11.0 in. wc / 11.0 po. c.e.

(For the purpose of input adjustment / dans le but de régler l’alimenation)

     (1.25 kPa)

     (2.74 kPa)

Manifold pressure / Pression de la tuyauterie:     Maximum

3.8 in. wc / 3.8 po. c.e.

11.0 in. wc / 11.0 po. c.e.

     (.95 kPa)

     (2.74 kPa)

                                     Minimum

1.1 in. wc / 1.1 po. c.e.

2.9 in. wc / 2.9 po. c.e.

     (.27 kPa)

     (.72 kPa)

Orifice Size / Diametre de l’injectuer:

# 45

# 55

Input BTU/hr / Entree BTU/h:

Max.:   21,000

Max.:   21,000

Min.:    10,500

Min.:    10,500

VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL
FOYER AU GAZ À ÉVACUATION - NE PAS UTILISER AVEC DU COMBUSTIBLE SOLIDE.

ANS Z21.88-1998 / CSA 2.33-1998 Vented Gas Fireplace Heater
CAN/CGA 2.17-M91 Gas-Fired Appliance For Use At High Altitudes., UL 307B-95

This appliance may be converted to a Vented Room Heater with optional "B-Vent Adapter" / Cet appareil pout être
converti à un Radiateur Ventile avec facultatif "B-Vent Adapter"

VENTED ROOM HEATER / RADIATEUR VENTILE - Report No. 476-1494.   

ANS Z21.11.1-1991 Vented Heaters,

CAN1-2.1-M86 Gas-Fired Vented Room Heaters., CAN/CGA 2.17-M91 Gas-Fired Appliance For Use At High Altitudes

Blower electrical rating:  115v, 60hz, 0.5A / Normes electriques du ventilateur:  115v, 60hz, 0.5 A.
Optional components: Fan Kit (OXFD.Blow), B-Vent Adapter / Éléments facultatifs: Ventilateur (OXFD.Blow), B-Vent Adapter.
This appliance equipped for altitudes 0 - 4500 ft. (0 - 1372 m) / Cet unite est concu pour des altitudes variant entre 0 - 4500
pieds (0 - 1372 m). Also certified for installation in a bedroom or a bedsitting room / Aussi certifié pour installation dans une
chambre à coucher ou une salle de séjour.  This appliance must be installed in accordance with local codes, if any; if none,
follow the National Fuel Gas Code, ANSI Z223.1, or Canadian Installation Codes, CAN/CGA-B149.  Installer l'appareil selon les
codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation National Fuel Gas Code, ANSI
Z223.1 ou Canadian Installation Codes, CAN/CGA-B149 en vigueur.

MANUFACTURED (MOBILE) HOME / FABRIQUEZ (MOBILE) MAISON:  May be installed in Manufactured Homes after the "first
sale" - See Instructions.  Pouvez être installés dans a Fabriqué des Maisons après le "première vente"- Voit des Directives.
Install in accordance with the current standard Mobile Homes, CAN/CSA Z240 MH (in CANADA), and the Manufacturer's Home
Construction and Safety Standard, Title 24 CFR, Part 3280, or the current Standard for Fire Safety Criteria for Manufactured
Home Installations, Sites, and Communities ANSI/NFPA 501A, (in the U.S.A.).  Cet appareil diot être installé conformemént
aux exigences de la norme CAN/CSA Z240 MH en vigueur de l'ACNOR, Installations de gaz dans les Constructions Mobiles.

This appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket,
permanently located, manufactured (mobile) home where not prohibited by local codes. See owners manual for details. This
appliance is not convertible for use with other gases, unless a certified kit is used.
Cet appareil doit être utilisé uniquement avec le type de gaz indiqué sur la plaque signalétique et peut être installé dans une
maison préfabriquée (mobile) installée à demeure si les règlements locaux le permettent. Voir la notice du propriétaire pour
plus de détails. Cet appareil ne peut être converti à d'autres gaz sauf si une trousse de conversion certifiée est utilisée.
This vented gas fireplace heater is not for use with air filters. / Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.

MINIMUM CLEARANCES TO COMBUSTIBLES / DEGAGEMENT DES MATIERES INFLAMMABLES
Left and Right side are determined when facing the front of the appliance. / Les côtés droit et gauche se determinent en
se mettant devant l’appareil et en lui faisant face.
Recommended service clearance from Right Sidewall to Appliance of 12 in. (305 mm) / II est recommander de laissier
un minimum de 12 po. (305 mm) entre le mur de côté et l'appareil afin de permettre acces de service.

Clearances to Combustibles

Regular Installation

Alcove Installation

Sidewall to Appliance/Du mur lateral a l’appareil

3 in./ 3 po.

(76 mm)

4 3/4 in./4 3/4 po.

(120.6 mm)

Backwall to Appliance/Du mur arriere a l’appareil

1 in./ 1 po.

(25 mm)

1 in./1 po.

(25 mm)

Corner to Appliance/D’un coin a l’appareil

1 in./ 1 po.

(25 mm)

N/A

(N/A)

Alcove Size /

48 in.   Wide Min.

48 po.     Large Min.

Grandeur de l'alcôve

24 in.   Deep Max.

24 po.     Profond Max.

60 in.   High Min.

60 po.     Haut Min.

WARNING:  Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage.
Refer to the owner’s information manual provided with this appliance.   For assistance or additional information, consult a
qualified installer, service agency or the gas supplier.
AVERTISSEMENT:  Une installation, un réglage, une modification, une réparation ou un entretien mal effectué peut causer
des dommages à la propriété ou des blessures.  Voir la notice de l'utilisateur qui accompagne l'appareil.  Pour de l'aide ou
d'autres renseignements consultez un installateur, ou un technicien agréé ou le fournisseur de gaz.

Pacific Energy Fireplace Products Ltd.
Duncan, British Columbia, Canada

WH-

REPORT NO.

476-1494 (SEP. 98)

WH-

MODEL/

  SERIES/

MODELE:

 THE OXFORD

  SERIE:

  A

Made in Canada / Fabrique au Canada

Certified for Canada and U.S.A. /
Certifié pour Canada et U.S.A.

171198

5050.713

1-OXFD-1

f i r e - p a r t s . c o m

Summary of Contents for The Oxford

Page 1: ...s supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier IMPORTAN...

Page 2: ...ALL INSTALLATION 7 CORNER INSTALLATION 8 BASEMENT INSTALLATION 10 ATTACHMENT TO FLOOR 10 ALTERNATE VENTING 11 VENT TERMINAL INSTALLATION 15 GLASS FRONT REMOVAL 16 LOG SET 17 GLOWING EMBERS 17 FIRST FI...

Page 3: ...ved cracked or broken Replacement of glass should be done by a licensed or qualified service person Do not strike or otherwise impact the glass in anyway that may cause ittobreak Iftheglassbecomescrac...

Page 4: ...ttom of the control assembly 5 Connect burner switch wires to the back of the rocker switch 6 Insert valve knob extensions through the control panel and onto their corresponding valve knobs Fig 2 7 In...

Page 5: ...ired Alcove sidewall to appliance clearance is listed at 4 3 4 A 10 clearance is recommended to center the appliance in a 48 minimum wide Alcove Sidewall to Appliance 3 in 76 mm Rearwall to Appliance...

Page 6: ...ON PRECAUTIONS The Oxford Heater installation and venting must conform with local codes or in the absence of local codes with the current Canadian Installation Code CAN CGA B149 in Canada or the curre...

Page 7: ...ll thickness and or rear clearance of the stove Measure the wall thickness from the finished trim collar surface to the exterior mounting surface for the vent terminal Add 1 4 inch plus rear clearance...

Page 8: ...6 Attach the coaxial 45 elbow LB 45 to the unit Slide the 5 inch inner elbow pipe 1 inch over top of the collar and secure with three sheet metal screws Seal the joint with high temperature silicone N...

Page 9: ...9 Fig 8 MAXIMUM MAXIMUM MAXIMUM MAXIMUM MAXIMUM fire parts com...

Page 10: ...gh temperature silicone and secured with screws 3 Continue adding vent components per the pre planned system configuration Support spacer must be used for each 6 feet of vertical and horizontal run Th...

Page 11: ...are main tained Follow vent pipe manufacturer s instructions for assembly and installation ALTERNATE VENTING SIMPSON DURA VENT DIRECT VENT GS SYSTEM CAUTION UNDER NO CONDITION SHOULD COMBUSTIBLE MATER...

Page 12: ...nimum 6 vertical rise is required for a wall termination see Fig 9a For horizontal runs greater than 6 increase vertical rise equally Horizontal run must not exceed 8 feet Any combination of rise grea...

Page 13: ...to 30 feet is permited with no horizontal run If horizontal run is required ensure that vertical rise is equal or greater than run Horizontal run must not exceed 8 feet Combined vent length must not e...

Page 14: ...on Cap Vertical 991 Low Profile Termination Cap Vertical 980 Extended Vertical Termination Cap Vertical 930 Horizontal Square Termination Cap 984 Snorkel Termination Cap 36 981 Snorkel Termination Cap...

Page 15: ...rom the center line of the terminal 18 inches 46 cm minimum E clearance to unventilated soffit 18 inches 46 cm minimum F clearance to outside corner 8 inches 20 cm minimum G clearance to inside corner...

Page 16: ...damage Handle enamelled parts carefully to avoid chipping Window Frame Removal 1 Remove two wing nuts located at the base of the window frame 2 Grasp the sides of the frame and swing the bottom out t...

Page 17: ...y are very fragile Note Improper placement of logs may cause soot ing on internal parts and glass Step 2 Left Log Placement log 2 Step 3 Right Log Placement log 3 Step 4 Middle Twig Placement log 4 St...

Page 18: ...n gas valve knob clockwise past Pilot to Off position Note Knob cannot be turned from Pilot to Off unless knob is pushed in slightly Do not force 5 Wait five 5 minutes to clear out any gas Then smell...

Page 19: ...a comfortable temperature Turn the HI LO burner control knob to a desired setting As heat is required the Oxford heater will turn on or off automatically as needed Extend Shutdown To shutdown the appl...

Page 20: ...SC THERMO OPTIONAL WALL SWITCH OPTIONAL REMOTE CONTROL GASC REMOTE ROCKER SWITCH THERMOPILE GAS VALVE Fig 18 Recommended Thermostat Wire Size Wire Size Max Length 14 ga 100 ft 16 ga 60 ft 18 ga 40 ft...

Page 21: ...AL BASE OXFD 2546 16 FRONT OVERLAY OXFD 2599_ _ 17 WINDOW FRAME OXFD 2518 18 GLASS GASKET KIT MFSD 50671 19 REPLACEMENT GLASS 5034 1 20 FRONT FIREBOX PANEL 5097 661 21 LEFT FIREBOX PANEL 5097 662 22 R...

Page 22: ...22 NOTES fire parts com...

Page 23: ...01A in the U S A Cet appareil diot tre install conformem nt aux exigences de la norme CAN CSA Z240 MH en vigueur de l ACNOR Installations de gaz dans les Constructions Mobiles This appliance is only f...

Page 24: ...24 Pacific Energy Fireplace Products Ltd PO Box 1060 Duncan B C V9L 3Y2 Phone 250 748 1184 Web site http www pacificenergy net Printed in Canada fire parts com...

Reviews: