ADJACENT WALL

E

B

A

SIDE WALL

D

H

SIDE

FRONT

H

SIDE

G

BACK  I

HEATER

BACK WALL

ADJACENT WALL

070509-16 

VISTA and CLASSIC-C 

15

5055.3

SAFETY LABEL - Pacific VISTA and VISTA CLASSIC

CERTIFIED FOR CANADA AND U.S.A.

LISTED ROOM HEATER, SOLID FUEL TYPE.

ALSO FOR USE IN MOBILE HOMES

TESTED TO CAN/ULC S627-M93 AND UL 1482-98

REPORT NO. 6680 (AUG. 89)    SERIES:

C

   MODEL: 

VISTA CLASSIC 

DO NOT REMOVE THIS LABEL

•  INSTALL AND USE IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS.

•  CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND INSPECTION IN 

YOUR AREA.

•  DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE (USA. ONLY).

•  USE 6 INCH / 150MM DIAMETER MINIMUM 24 MSG BLACK OR LISTED CONNECTOR.

•  CONNECT TO A LINED MASONRY CHIMNEY SUITABLE FOR USE WITH SOLID FUELS.

•  DO NOT OBSTRUCT THE SPACE BENEATH THE HEATER.

•  SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASS

-

ING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING.

•  DO NOT PASS A CHIMNEY CONNECTOR THROUGH A COMBUSTIBLE WALL OR CEILING.

•  MINIMUM CLEARANCE BETWEEN SINGLE WALL CHIMNEY CONNECTOR AND COMBUSTIBLE MATERIALS-18INCHES/

455MM.  CLEARANCE MAY BE REDUCED BY THE USE OF LISTED PIPE SHIELDS, WALL PROTECTORS OR OTHER 

MEANS APPROVED BY LOCAL BUILDING OR FIRE OFFICIALS.

  HORIZONTAL CONNECTOR NOT PERMITTED IN MOBILE HOMES

 

AS TESTED - PIPE SHIELD MAY BE REqUIRED BY LOCAL AUTHORITIES.

*  COMBUSTIBLE ALCOVE SIZE : DEPTH - 3 FT. / .91 M MAX., HEIGHT 7 FT. / 2.1 M MIN., WIDTH 4 FT. / 1.2 M MIN.

  COMBUSTIBLE FLOOR MUST BE PROTECTED BY A CONTINUOUS NON-COMBUSTIBLE MATERIAL EXTENDED TO THE 

FRONT, SIDES AND BACK AS INDICATED.

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS

•  COMPONENTS REQUIRED FOR MOBILE HOME AND ALCOVE INSTALLATION: OUTSIDE AIR KIT, AND ONE OF THE 

FOLLOWING LISTED CONNECTORS:  SECURITY MODELS DP OR DC,  OLIVER MACLEOD MODEL PV,  RYDER MODEL 

E VENT,  SELKIRK METALBESTOS MODEL DS,  METAL FAB MODEL DW,  AMERI-TEC MODEL DBSP,  INDUSTRIAL 

CHIMNEY MODEL EXCEL ULTRA-BLACK, OR SIMPSON DURA-VENT MODEL DVL IN COMBINATION WITH ONE OF THE 

FOLLOWING COMPATIBLE CHIMNEY SYSTEMS:

IN CANADA -  SECURITY MODEL S2100,  OLIVER MACLEOD PROJET MODEL HT 3000,  SELKIRK SENTINEL MODEL CF,  

INDUSTRIAL CHIMNEY MODEL EXCEL 2100,  ENERGY VENT COMMANDER 5000.

IN USA -  SECURITY MODEL ASHT OR S2100,  OLIVER MACLEOD MODEL 3103 OR HT 3000,  SELKIRK METALBESTOS 

MODEL SS II,  METAL FAB MODEL 2100,  AMERI-TEC MODEL HS,  INDUSTRIAL CHIMNEY MODEL EXCEL 103HT,  SIMP

-

SON DURA-VENT MODEL DURA/PLUS AND DURA TECH.

  USE COMPONENTS SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.

•  APPLIANCE MUST BE INSTALLED WITH PEDESTAL OR LEG KIT ATTACHED.

•  OPTIONAL COMPONENTS - FAN KIT, FAN ELECTRICAL RATING: 115V, 60HZ, 80WATTS.

  DO NOT ROUTE POWER CORD BENEATH HEATER.

•  CAUTION: RISK OF EXCESSIVE TEMPERATURES - KEEP ASH DUMP CLOSED DURING FIRING OF THE HEATER.

•  OPERATE ONLY WITH FEED DOOR CLOSED.  OPEN TO FEED FIRE ONLY.

•  KEEP FURNISHINGS AND OTHER COMBUSTIBLE MATERIALS WELL AWAY FROM HEATER.

•  REPLACE GLASS ONLY WITH CERAMIC GLASS.

MADE IN CANADA

 

J   F   M   A   M   J   J   A   S   O  N   D

1998 

1999  2000  2001  2002  2003

DATE OF MANUFACTURE

MANUFACTURED BY:

PACIFIC ENERGY FIREPLACE PRODUCTS LTD.

PO. BOX 1060, DUNCAN, BC  V9L 3Y2

VST1-C-1a

VERTICAL CONNECTOR   HORIZONTAL CONNECTOR

  

A. SIDEWALL TO UNIT 

14 IN. / 355 MM 

14 IN. / 355 MM 

12 IN. / 305 MM 

12 IN. / 305 MM 

12 IN. / 305 MM 

12 IN. / 305 MM

B. BACKWALL TO UNIT 

15 IN. / 381 MM 

 13 IN. / 330 MM 

7 IN. / 178 MM 

 7 IN. / 178 MM 

11 IN. / 279 MM 

12 IN. / 305 MM

C. CORNER TO UNIT 

10 IN. / 254 MM 

10 IN. / 254 MM 

3 IN. / 76 MM 

3 IN. / 76 MM 

N/A 

8 IN. / 203 MM

D. SIDEWALL TO CONNECTOR 

23 IN. / 585 MM 

23 IN. / 585 MM  20.5 IN. / 521 MM  20.5 IN. / 521 MM  20.5 IN. / 521 MM  20.5 IN. / 521 MM

E. BACKWALL TO CONNECTOR  18 IN. / 457 MM 

 16 IN. / 406 MM  9.5 IN. / 241 MM   9.5 IN. / 241 MM  13.5 IN. / 343 MM  14.5 IN. / 370 MM

F.  CORNER TO CONNECTOR 

19 IN. / 483 MM 

19 IN. / 483 MM  11.5 IN. / 292 MM  11.5 IN. / 292 MM 

N/A  16.5 IN. / 419 MM

RESIDENTIAL CLOSE CLEARANCE 

INSTALLATION

USING DOUBLE WALL CONNECTOR

VERTICAL CONNECTOR   HORIZONTAL CONNECTOR

 

 

* ALCOVE

INSTALLATION

USING

DOUBLE WALL 

CONNECTOR

MOBILE HOME

INSTALLATION

USING

DOUBLE WALL 

CONNECTOR

HOT WHILE IN OPERATION.  DO NOT TOUCH.  KEEP CHILDREN, 

CLOTHING AND FURNITURE AWAY.  CONTACT MAY CAUSE SKIN 

BURNS.  SEE NAMEPLATE AND INSTRUCTIONS.

U.S. ENVIRONMENTAL PROTECTION 

AGENCY CERTIFIED TO COMPLY WITH 

JULY, 1990, PARTICULATE EMISSION 

STANDARDS

WH-

WH-

CAUTION

RESIDENTIAL INSTALLATION 

USING SINGLE WALL CONNECTOR

IN CANADA  G. 

18 INCHES / 455 MM

 

H. 

8 INCHES / 200 MM

 

I. 

8 INCHES / 200 MM

IN U.S.A. 

G. 

16 INCHES / 405 MM

 

H. 

4 INCHES / 102 MM

 

I. 

0 INCHES / 0 MM

5050.73

080801

PACIFIC VISTA 

Summary of Contents for Pacific VISTA

Page 1: ...IES C SAFETY NOTICE If this stove is not properly installed a house fire may result For your safety follow the installation directions Contact local building or fire officials about restrictions and i...

Page 2: ...AFETY AND MAINTENANCE 3 ASSEMBLY 4 MOBILE HOME INSTALLATION 6 RESIDENTIAL INSTALLATION 7 FLOOR PROTECTOR 7 COMBUSTION AIR 8 WOOD SELECTION 8 OPERATING 8 PROPER DRAFT 9 ASH REMOVAL 9 BAFFLE REMOVAL 9 O...

Page 3: ...nnect the detectors If necessary relocate them to reduce their sensitivity safety notice If this stove is not properly installed a house fire may re sult For your safety follow the installation direct...

Page 4: ...pedestal mounting holes with the studs on stove bottom 2 Secure in place with 1 2 nuts previously removed 3 Carefully place the unit in an upright position LEG KIT 1 With the unit on its back and remo...

Page 5: ...e Chimney Roof flashing Storm collar Hooded vent Attachment to floor for mobile homes Spark arrestor rain cap FIG 2 7 2 1 m Minimum Ceiling Height 58 1473 mm Minimum 48 1219 mm Minimum The chimney may...

Page 6: ...upplier for installation advice PROCEDURE Note See Combustion Air section on page 8 1 Position stove and floor protection with the clearances as stated on the label or as in Figure 1a and 1b page 4 5...

Page 7: ...spointingdown This will carry any liquid creosote or condensation back into the stove Thechimneyconnectorshouldnotpassthroughatticorroof space closet or similar concealed space or floor ceiling wall o...

Page 8: ...der no circumstances should you attempt to barbecue in this heater HOW TO TEST YOUR WOOD Add a large piece of wood to the stove when it has a good large bed of coals It is dry if it is burning on more...

Page 9: ...rough appliance and chimney connector joints indicates inadequate draft ASH REMOVAL When ever ashes get 3 to 4 inches deep in your firebox and whenfirehasburneddownandcooled removeexcessashes Leave an...

Page 10: ...sket leakage Replace gasket Check latch EXCESSIVE CREOSOTE BUILDUP See 1 2 3 above LOW HEAT OUTPUT 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or re...

Page 11: ...excessively open When wood is burned slowly it produces tar and other or ganic vapours which combine with expelled moisture to form creosote The creosote vapours condense in the relatively cool chimn...

Page 12: ...CAST VSNI 9 DOOR HANDLE ASSEMBLY WODC 4147 10 BOOST MANIFOLD 2105 11a FIREBRICK 1 1 2 x 4 1 2 x 1 1 4 248 11b FIREBRICK 3 x 4 1 2 x 1 1 4 247 11c FIREBRICK 4 x 4 1 2 x 1 1 4 246 11d FIREBRICK 9 x 4 1...

Page 13: ...7 11c FIREBRICK 4 x 4 1 2 x 1 1 4 246 11d FIREBRICK 9 x 4 1 2 x 1 1 4 5096 99 FIREBRICK SET BRIC VISTA 12a BRICK RAIL LEFT 2122 12b BRICK RAIL RIGHT 2122 5 13 RAIL EXTENSIONS 2 pc required 2123 14 BAF...

Page 14: ...the heater in the upright position install firebricks as follows First install 4 full size firebricks against the rear wall Next install the side firebricks 2 full size each side Lastly place 4 full...

Page 15: ...JET MODEL HT 3000 SELKIRK SENTINEL MODEL CF INDUSTRIAL CHIMNEY MODEL EXCEL 2100 ENERGY VENT COMMANDER 5000 IN USA SECURITY MODEL ASHT OR S2100 OLIVER MACLEOD MODEL 3103 OR HT 3000 SELKIRK METALBESTOS...

Page 16: ...16 VISTA and CLASSIC C 070509 16 5055 3 Printed in Canada PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan BC V9L 6V8 Phone 888 715 2398 Web site www pacificenergy net...

Reviews: