OPTIONAL BLOWER
The optional blower kit (# WODC.BLOW) is equipped with
a three prong power cord and may be installed at any time.
Follow installation instructions supplied with the kit. Route
power supply cord away from heater.
Electrical rating: 115 volt A.C.-1.02 amps.
Fan output rating: 125 CFM
BLOWER OPERATION
Proper blower speed matched with air control setting will en-
sure peak performance from your stove. Operate as follows:
1) Air control set to "H" (high), operate blower on "High".
2) Air control set between "L" and "H" (low and high), oper-
ate blower on "Medium".
3) Air control set to "L" (low), operate blower on "Low".
When re-loading fuel, turn off blower for up to 30 minutes
to allow stove to reach proper operating temperature.
TROUBLESHOOTING
PROBLEM
CAUSE
CURE
GLASS IS DIRTY
1. Wood is wet
- Use dry wood
2. Turning down air control
- Do not turn down until:
too soon
a) there is a good bed of coals
b) the wood is charred
3. Draft too low
- Improper chimney height and/
or diameter
- Chimney plugged or restricted, check flue
- Provide outside air for combustion
4. Door gasket leakage
- Replace gasket
- Check latch
EXCESSIVE CREOSOTE BUILDUP
See 1,2,3, above.
LOW HEAT OUTPUT
1. Wood is wet
- Use dry wood
2. Fire too small
- Build a larger fire
3. Draft too low
- Chimney plugged or restricted.
Inspect and clean
WON'T BURN OVERNIGHT
1. Air control is set too high
- Set control lower
OVERNIGHT
2. Not enough wood
- Unsplit wood is preferred
for overnight burns
3. Draft too high
- Excessive chimney height and/or diameter
STOVE WON'T BURN
1. Combustion air supply blocked
- Check outside air supply for
obstruction
- Check that room air cover is
removed
2. Draft too low
- Chimney plugged or restricted
Inspect and clean
- Chimney oversized or otherwise
unsuitable, Consult dealer
Automatic:
To operate the blower automatically, set the
rocker switch on the side of the fan housing to "Auto" and set
the speed control to desired setting. This will allow the fan
to turn on as the stove heats up to operating temperature. It
will also shut the blower off after the fire has gone out and
the unit cooled to below a useful heat output range.
Manual:
To manually operate the blower, set the rocker
switch to "Man" and set the speed control to desired setting.
This will bypass the sensing device and allow full control
of the blower.
Switching from "Auto" to "Man" or selecting speed may be
done anytime.