PACIFIC FP30 190712-28
7
FIG. #5
NUTS
Blower
Replacement
1. The blower is located in the bottom rear compartment
of the woodstove and can be accessed by removing the
access panel on the bottom of the fi rebox. Remove the
bricks to expose the access panel, then remove the 8
bolts or screws holding the access panel using a 7/16"
socket or wrench(Fig. #1).
2. Loosen the hose clamp on the 3" fl ex vent at the air box
towards the front of the woodstove and disconnect the
fl ex vent. Gently push the fl ex vent clear of the access
opening(Fig. #2 & #3).
3. Disconnect the wire lead of the blower from the electri-
cal terminal block and the male/female connection to the
Thermo Switch .
4. Remove the two wingnuts securing the blower mounting
bracket(Fig. #4).
5. Gently lift the bracket and slide the blower towards the
front of the woodstove.
6. Lift the blower up and out of the woodstove through he
access opening.
7. Remove the nuts attaching the blower to the bracket and
replace blower(Fig. #5).
8. Reverse the process to re-install blower.
FIG. #1
FIG. #2
FIG. #3
FIG. #4
BOLTS
3" FLEX TUBE
3" FLEX TUBE
WINGNUTS
110VAC COMMON
GROUND
110VAC SWITCHED
Blower
Thermo
Switch
Electrical Rating : 115 V, 60 Hz, 1.1A
120412
5050.7434
MALE/FEMALE
CONNECTION
TERMINAL
BLOCK
USE ONLY COPPER CONDUCTORS