PACIFIC FP30 190712-28
27
Label
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629, ICC
LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629, ICC
(INDUSTRIAL CHIMNEY COMPANY). AUX ÉTATS-UNIS - CHEMINÉE HOMOLOGUÉE UL-103 HT.
(INDUSTRIAL CHIMNEY COMPANY). AUX ÉTATS-UNIS - CHEMINÉE HOMOLOGUÉE UL-103 HT.
• INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.
• LES PARTIES DU FOYER INCORPORANT DES CONDUITS CHAUDS OU FROIDS DOIVENT ÊTRE ENCHÂSSÉES,
CONFORMÉMENT AUX INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.
• CONTACTEZ LES AGENTS LOCAUX DU CODE DU BÂTIMENT OU DU SERVICE-INCENDIE POUR LES RESTRICTIONS, PERMIS
D’INSTALLATION ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION.
• NE RACCORDEZ PAS CE FOYER À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL
• NE PAS OBSTRUER PAS LES OUVERTURES DEVANT LE FOYER, NI RESTREINDRE L’ALIMENTATION D’AIR NÉCESSAIRE POUR
LE FONCTIONNEMENT NORMAL DU FOYER, TEL QUE SPÉCIFIÉ DANS LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION
FOURNIES AVEC L’APPAREIL. LA PROVISION INADEQUATE D’AIR POUR COMBUSTION, MAI DE VENTILATION ET DILUTION A POUR
RESULTAT L’OPERATION DANGEREUSE DE CECI ET AUTRES APPAREILS.
• VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT, POUR LES PRÉCAUTIONS EXIGÉES LORSQU’UNE
CHEMINÉE TRAVERSE UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES.
• COMPOSANTS OPTIONNELS: KIT DE PRISE D’AIR, KIT DE CONDUITS DE DISTRIBUTION DE CHALEUR (PIÈCE no FP30.GVKIT).
• UTILISEZ LES COMPOSANTS SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION DE PACIFIC ENERGY.
• UTILISEZ SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE. NE L’OUVREZ QUE POUR ALIMENTER LE FEU.
• POUR COMBUSTIBLE SOLIDE SEULEMENT.
• REMPLACEZ LA VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE.
• LA SOUFFLERIE CLASSEMENT ELECTRIQUE 115V, 60 Hz, 1.0AMP
• CETTE CHEMINEE n’A pas ETE ESSAYEE AVEC UN UNVENTED JOURNAL DE GAZ A REGLE. POUR REDUIRE LE RISQUE DE
FEU OU BLESSURE, LE PAS INSTALLE UN UNVENTED JOURNAL DE GAZ A REGLE DANS CHEMINEE.
CERTIFIED FOR CANADA AND U.S.A.
LISTED FACTORY BUILT FIREPLACE.
CERTIFIED TO ULC S610-M87 AND
CONFORMS TO UL 127-2011/
FOYER PRÉFABRIQUÉ HOMOLOGUÉ / CERTIFIÉ POUR UTILISATION AU CANADA
ET AUX É.-U.TESTÉ SELON ULC S610-M87 ET UL 127-2011.
SERIES/SÉRIE:
A
MODEL/ MODÈLE:
FP30
• INSTALL AND USE IN ACCORDANCE WITH THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE
APPLIANCE. • AREAS OF THE FIREPLACE INCORPORATING WARM OR COLD AIR DUCTS SHALL BE ENCLOSED IN ACCORDANCE
WITH THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE.
• CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND INSPECTION IN YOUR
AREA. • DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE
• DO NOT OBSTRUCT THE OPENINGS IN FRONT OF THE FIREPLACE OR OTHERWISE RESTRICT SUPPLY AIR NECESSARY FOR
NORMAL FIREPLACE OPERATION
AS SPECIFIED IN INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE
APPLIANCE. INADEQUATE AIR SUPPLY FOR COMBUSTION, VENTILATION AND DILUTION MAY RESULT IN DANGEROUS OPERATION
OF THIS AND OTHER APPLIANCES.
• SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING A
CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. CHIMNEY SYSTEM MUST BE LISTED TO: IN CANADA - USE ONLY ICC
IN CANADA - USE ONLY ICC
EXCEL CHIMNEY LISTED TO ULC-S-629, IN USA - UL-103 HT LISTED CHIMNEY
EXCEL CHIMNEY LISTED TO ULC-S-629, IN USA - UL-103 HT LISTED CHIMNEY
• OPTIONAL COMPONENTS: FRESH AIR KIT, GRAVITY HEAT DUCT KIT PART# FP30.GVKIT.
• OPERATE ONLY WITH FEED DOOR CLOSED. OPEN TO FEED FIRE ONLY.
• FOR SOLID WOOD FUEL ONLY. • BLOWER ELECTRICAL RATING 115V, 60HZ, 1.0AMP • REPLACE GLASS ONLY WITH 5mm
CERAMIC GLASS.
• DO NOT USE OR INSTALL COMPONENTS OR PRODUCTS NOT SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS.
DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS PRODUCT.
• THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT
INSTALL AN UNVENTED GAS LOG SET INTO FIREPLACE.
A. CHASE ENCLOSURE WIDTH/ LARGEUR DE CLÔTURE DE
POURSUITE
60 in. / 1.52 m
B. BACKWALL TO CONNECTOR/ MUR ARR. AU TUYAU de RAC. 10 in./254 mm
C. BACKWALL TO UNIT/ MUR ARRIÈRE AU FOYER 1 in. / 25 mm
D. FRAMING OPENING/ OUVERTURE DE CADRAGE 51 in /1.3 m
E. CORNER TO CONNECTOR/ COIN AU TUYAU de RACCOR. 39 in./991 mm
F. SIDEWALL TO CONNECTOR/ MUR LAT. au TUYAU de RAC. 28 in./711 mm
G. NON-COMBUSTIBLES ONLY ABOVE UNIT TO CEILING/
NON-COMBUSTIBLES SEULEMENT AU-DESSUS FOYER À 18 in. / 457 mm
PLAFOND
H. TOP OF DOOR TO MANTEL/ HAUT DE PORTE AU MANTEAU
J. CEILING TO UNIT/ DU PLAFOND AU FOYER
26 in. / 660 mm
K. FLOOR PROTECTION FROM FRONT OF UNIT/
PROTECTEUR de PLANCHER À L’AVANT DU FOYER 18 in. / 457 mm
K. FLOOR PROTECTION TO SIDE OF UNIT/
PROTECTEUR de PLANCHER AU CÔTÉ DU FOYER 8 in./203 mm
CLEARANCES TO ALL STANDOFFS/ DÉGAGEMENTS 0 in. / 0 mm
DO NOT REMOVE THIS LABEL/ NE RETIREZ PAS CETTE
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS/ DÉGAGEMENTS MINIMUMS AUX MATÉRIAUX
COMBUSTIBLES
SN-
C
A
B
F
E
D
D
J
G
H
K
K
CAN.
K
U.S.A.
ETL#4001507
MANUFACTURED BY/ FABRIQUÉ PAR :
PACIFIC ENERGY FIREPLACE PRODUCTS LTD.
2975 ALLENBY RD., DUNCAN, BC V9L 6V8
CAUTION
IN CANADA: “K” IS FROM THE SIDE FACING FLANGE/AU CANADA : «K» EST MESURÉ À PARTIR DE LA FAÇADE LATÉRALE DU
FOYER.///IN U.S.A : “K” IS FROM THE SIDE OF THE FIRING DOOR OPENING/AUX ÉTATS-UNIS : «K» EST MESURÉ À PARTIR DU
BORD DE L’OUVERTURE DE LA PORTE DE CHARGEMENT.
MADE IN CANADA/ FABRIQUÉ AU CANADA
2012
2013
2014
2015
2016 2017
J F M A M J J A S O N D
DATE OF MANUFACTURE/ DATE DE FABRICATION
FP30-1
HOT WHILE IN OPERATION. DO NOT TOUCH.
KEEP CHILDREN, CLOTHING AND FURNITURE
AWAY. CONTACT MAY CAUSE SKIN BURNS. SEE NAMEPLATE AND
INSTRUCTIONS./ DEVIENT TRÈS CHAUD. NE TOUCHEZ PAS. ÉLOIGNEZ LES
ENFANTS, LES VÊTEMENTS ET LES MEUBLES. UN CONTACT PEUT CAUSER
DES BRÛLURES. VOIR LA PLAQUE SIGNALÉTIQUE ET LES INSTRUCTIONS.
U.S. ENVIRONMENTAL PROTECTION AGENCY CERTIFIED
TO COMPLY WITH JULY, 1990, PARTICULATE EMISSION
STANDARDS/ CERTIFIÉ CONFORME AUX NORMES
SUR LES ÉMISSIONS DE PARTICULES (JUILLET 1990).
270612
5050.7622
IN CANADA: “H” IS 42”(1.07m) WITHOUT A GRAVITY VENT INSTALLED AND 34”(864mm) WITH A GRAVITY VENT INSTALLED.
IN THE U.S.A.: “H” IS 34”(864mm)
***
***
601
Label Location
The rating label is located beneath the
fi rebox on the casing fl oor and can be
viewed by removing the access cover
in the bottom of the fi rebox. There is
an additional clearances label on the
right side, of the fi replace casing.
RATING LABEL