PACIFIC FP30  190712-28 

27

Label

LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629, ICC

 LE SYSTÈME DE CHEMINÉE DOIT ÊTRE HOMOLOGUÉ COMME SUIT : AU CANADA - CHEMINÉE HOMOLOGUÉE ULC-S-629, ICC 

(INDUSTRIAL CHIMNEY COMPANY). AUX ÉTATS-UNIS - CHEMINÉE HOMOLOGUÉE UL-103 HT.

(INDUSTRIAL CHIMNEY COMPANY). AUX ÉTATS-UNIS - CHEMINÉE HOMOLOGUÉE UL-103 HT.

•     INSTALLEZ ET UTILISEZ SELON LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.
•    LES PARTIES DU FOYER INCORPORANT DES CONDUITS CHAUDS OU FROIDS DOIVENT ÊTRE ENCHÂSSÉES,  

 

    CONFORMÉMENT AUX INSTRUCTIONS D’INSTALLATION ET D’UTILISATION FOURNIES AVEC LE FOYER.
•    CONTACTEZ LES AGENTS LOCAUX DU CODE DU BÂTIMENT OU DU SERVICE-INCENDIE POUR LES RESTRICTIONS, PERMIS  
    D’INSTALLATION ET EXIGENCES D’INSPECTION DANS VOTRE RÉGION.
•    NE RACCORDEZ PAS CE FOYER À UN CONDUIT DE CHEMINÉE DESSERVANT UN AUTRE APPAREIL
•     NE PAS OBSTRUER PAS LES OUVERTURES DEVANT LE FOYER, NI RESTREINDRE L’ALIMENTATION D’AIR NÉCESSAIRE POUR 
LE FONCTIONNEMENT NORMAL DU FOYER, TEL QUE SPÉCIFIÉ DANS LES INSTRUCTIONS D’INSTALLATION ET D’UTILISATION 
FOURNIES AVEC L’APPAREIL. LA PROVISION INADEQUATE D’AIR POUR COMBUSTION, MAI DE VENTILATION ET DILUTION A POUR 
RESULTAT L’OPERATION DANGEREUSE DE CECI ET AUTRES APPAREILS.
• VOIR LE CODE DU BÂTIMENT LOCAL ET LES INSTRUCTIONS DU FABRICANT, POUR LES PRÉCAUTIONS EXIGÉES LORSQU’UNE 

CHEMINÉE TRAVERSE UN MUR OU PLAFOND EN MATÉRIAUX COMBUSTIBLES.

•   COMPOSANTS OPTIONNELS: KIT DE PRISE D’AIR, KIT DE CONDUITS DE DISTRIBUTION DE CHALEUR (PIÈCE no FP30.GVKIT).
•   UTILISEZ LES COMPOSANTS SPÉCIFIÉS DANS LES INSTRUCTIONS D’INSTALLATION DE PACIFIC ENERGY.
•   UTILISEZ SEULEMENT AVEC LA PORTE DE CHARGEMENT FERMÉE. NE L’OUVREZ QUE POUR ALIMENTER LE FEU.
•  POUR COMBUSTIBLE SOLIDE SEULEMENT.
•  REMPLACEZ LA VITRE SEULEMENT PAR UNE VITRE EN CÉRAMIQUE.
•  LA SOUFFLERIE CLASSEMENT ELECTRIQUE 115V, 60 Hz, 1.0AMP
•  CETTE CHEMINEE n’A pas ETE ESSAYEE AVEC UN UNVENTED JOURNAL DE GAZ A REGLE. POUR REDUIRE LE RISQUE DE 

FEU OU BLESSURE, LE PAS INSTALLE UN UNVENTED JOURNAL DE GAZ A REGLE DANS CHEMINEE.  

CERTIFIED FOR CANADA AND U.S.A.
LISTED FACTORY BUILT FIREPLACE.
CERTIFIED TO ULC S610-M87 AND 
CONFORMS TO UL 127-2011/
FOYER PRÉFABRIQUÉ HOMOLOGUÉ / CERTIFIÉ POUR UTILISATION AU CANADA 
ET AUX É.-U.TESTÉ SELON ULC S610-M87 ET UL 127-2011.        

 

 

 

 

 

 

           SERIES/SÉRIE: 

A

MODEL/ MODÈLE:

FP30

•    INSTALL AND USE IN ACCORDANCE WITH THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE  

 

 APPLIANCE.   •  AREAS OF THE FIREPLACE INCORPORATING WARM OR COLD AIR DUCTS SHALL BE ENCLOSED IN ACCORDANCE 
WITH THE INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE APPLIANCE. 

 

 

•    CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS, INSTALLATION PERMIT AND INSPECTION IN YOUR  
    AREA.  • DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE 
•   DO NOT OBSTRUCT THE OPENINGS IN FRONT OF THE FIREPLACE OR OTHERWISE RESTRICT SUPPLY AIR NECESSARY FOR 
NORMAL FIREPLACE OPERATION  

AS SPECIFIED IN INSTALLATION AND OPERATING INSTRUCTIONS SUPPLIED WITH THE  

APPLIANCE. INADEQUATE AIR SUPPLY FOR COMBUSTION, VENTILATION AND DILUTION MAY RESULT IN DANGEROUS OPERATION 
OF THIS AND OTHER APPLIANCES.
•  SEE LOCAL BUILDING CODE AND MANUFACTURER'S INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING A 
  CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING. CHIMNEY SYSTEM MUST BE LISTED TO: IN CANADA - USE ONLY ICC

IN CANADA -  USE ONLY ICC 

EXCEL CHIMNEY LISTED TO ULC-S-629, IN USA - UL-103 HT LISTED CHIMNEY

EXCEL CHIMNEY LISTED TO ULC-S-629, IN USA -  UL-103 HT LISTED CHIMNEY

•  OPTIONAL COMPONENTS: FRESH AIR KIT, GRAVITY HEAT DUCT KIT PART# FP30.GVKIT.
•  OPERATE ONLY WITH FEED DOOR CLOSED.  OPEN TO FEED FIRE ONLY.
•  FOR SOLID WOOD FUEL ONLY.    •  BLOWER ELECTRICAL RATING 115V, 60HZ, 1.0AMP   • REPLACE GLASS ONLY WITH 5mm 

CERAMIC GLASS.

•  DO NOT USE OR INSTALL COMPONENTS OR PRODUCTS NOT SPECIFIED IN PACIFIC ENERGY INSTALLATION INSTRUCTIONS. 

DO NOT USE A FIREPLACE INSERT OR OTHER PRODUCTS NOT SPECIFIED FOR USE WITH THIS PRODUCT.

•  THIS FIREPLACE HAS NOT BEEN TESTED WITH AN UNVENTED GAS LOG SET. TO REDUCE RISK OF FIRE OR INJURY, DO NOT 

INSTALL AN UNVENTED GAS LOG SET INTO FIREPLACE.

A. CHASE ENCLOSURE WIDTH/ LARGEUR DE CLÔTURE DE
 POURSUITE           

                        60 in. / 1.52 m 

B. BACKWALL TO CONNECTOR/ MUR ARR. AU TUYAU de RAC.  10 in./254 mm 
C. BACKWALL TO UNIT/ MUR ARRIÈRE AU FOYER                           1 in. / 25 mm 
D. FRAMING OPENING/ OUVERTURE DE CADRAGE                          51 in /1.3 m 
E.  CORNER TO CONNECTOR/ COIN AU TUYAU de RACCOR.         39 in./991 mm 
F.  SIDEWALL TO CONNECTOR/ MUR LAT. au TUYAU de RAC.       28 in./711 mm
G. NON-COMBUSTIBLES ONLY ABOVE UNIT TO CEILING/           
NON-COMBUSTIBLES SEULEMENT AU-DESSUS FOYER À          18 in. / 457 mm
 PLAFOND
H. TOP OF DOOR TO MANTEL/ HAUT DE PORTE AU MANTEAU                        
J.  CEILING TO UNIT/ DU PLAFOND AU FOYER 

                       26 in. / 660 mm

K. FLOOR PROTECTION FROM FRONT OF UNIT/ 
PROTECTEUR de PLANCHER À L’AVANT DU FOYER                    18 in. / 457 mm
K. FLOOR PROTECTION TO SIDE OF UNIT/ 
PROTECTEUR de PLANCHER AU CÔTÉ DU FOYER                           8 in./203 mm
CLEARANCES TO ALL STANDOFFS/ DÉGAGEMENTS                        0 in. / 0 mm

DO NOT REMOVE THIS LABEL/ NE RETIREZ PAS CETTE 

MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS/ DÉGAGEMENTS MINIMUMS AUX MATÉRIAUX 
COMBUSTIBLES

SN-

C

A

B

F

E

D

D

J

G

H

K

K

CAN.

K

U.S.A.

ETL#4001507

MANUFACTURED BY/ FABRIQUÉ PAR :

PACIFIC ENERGY FIREPLACE PRODUCTS LTD.

2975 ALLENBY RD., DUNCAN, BC  V9L 6V8

CAUTION

IN CANADA: “K” IS FROM THE SIDE FACING FLANGE/AU CANADA : «K» EST MESURÉ À PARTIR DE LA FAÇADE LATÉRALE DU 
FOYER.///IN U.S.A : “K” IS FROM THE SIDE OF THE FIRING DOOR OPENING/AUX ÉTATS-UNIS : «K» EST MESURÉ À PARTIR DU
BORD DE L’OUVERTURE DE LA PORTE DE CHARGEMENT.

MADE IN CANADA/ FABRIQUÉ AU CANADA

2012 

2013 

2014 

2015 

2016   2017

J   F   M   A   M   J   J   A   S   O  N   D

DATE OF MANUFACTURE/ DATE DE FABRICATION

FP30-1

HOT WHILE IN OPERATION.  DO NOT TOUCH.  
KEEP CHILDREN, CLOTHING AND FURNITURE
 AWAY.  CONTACT MAY CAUSE SKIN BURNS.  SEE NAMEPLATE AND 
INSTRUCTIONS./ DEVIENT TRÈS CHAUD. NE TOUCHEZ PAS. ÉLOIGNEZ LES 
ENFANTS, LES VÊTEMENTS ET LES MEUBLES. UN CONTACT PEUT CAUSER 
DES BRÛLURES. VOIR LA PLAQUE SIGNALÉTIQUE ET LES INSTRUCTIONS.

U.S. ENVIRONMENTAL PROTECTION AGENCY CERTIFIED 
TO COMPLY WITH JULY, 1990, PARTICULATE EMISSION 
STANDARDS/ CERTIFIÉ CONFORME AUX NORMES
SUR LES ÉMISSIONS DE PARTICULES (JUILLET 1990).

270612

5050.7622

         IN CANADA: “H” IS 42”(1.07m) WITHOUT A GRAVITY VENT INSTALLED AND 34”(864mm) WITH A GRAVITY VENT INSTALLED.
IN THE U.S.A.: “H” IS 34”(864mm)

***

***

601

Label Location

The rating label is located beneath the 
fi rebox on the casing fl oor and can be 
viewed by removing the access cover 
in the bottom of the fi rebox. There is 
an additional clearances label on the 
right side, of the fi replace casing.

RATING LABEL

Summary of Contents for PACIFIC FP30

Page 1: ...s Contact local building or fire officials about restrictions and installation inspection requirements in your area TESTED and LISTED to CAN ULC S610 M87 AND UL 127 Meets the Environmental Protection...

Page 2: ...Chimney Fires 4 In the event of a Chimney Fire 4 Avoiding a Chimney Fire 4 Operation 5 Wood Selection 5 How to Test Your Wood 5 Lighting for the First Time 5 Lighting a Fire 5 Normal Operation 5 Resta...

Page 3: ...inspect seals and replace if necessary 7 DOOR GLASS Replacement glass can be obtained from your dealer Use 11 3 8 x 21 5 8 x 5 mm WARNING DO NOT SUBSTITUTE GLASS WITH ANY OTHER TYPE MATERIAL OTHER TH...

Page 4: ...itable and must be lived with Regular inspection and cleaning is the solution The use of dry seasoned wood and ample combustion air will help to minimize the buildup Chimney Fires The result of excess...

Page 5: ...ss with several pieces of dry kindling Add a few small pieces of dry wood on top 3 Ignite the paper and close the door Depending on length of chimney installation you may need to leave door open appro...

Page 6: ...wood will be producing 9375 BTU s per hour aver age 7500 BTU x 10 lbs 8hrs 9375 BTU s per hr If you put 20 lbs of wood in your stove for eight hour burn you will get 18 750BTU sperhr 7500BTUx20lbs 8hr...

Page 7: ...Fig 2 3 3 Disconnect the wire lead of the blower from the electri cal terminal block and the male female connection to the Thermo Switch 4 Remove the two wingnuts securing the blower mounting bracket...

Page 8: ...llation This package contains 19 full size firebricks as well as 3 various cut size bricks With the woodstove in the upright position install firebricks as follows 1 Place the firebricks on the bottom...

Page 9: ...d choose a location where the chimney will pass through the house without cutting floor or roof joists OUTSIDE AIR INTAKE THIS LOCATION NOT RECOMMENDED THIS LOCATION OK RECOMMENDED LOCATIONS FIG 6 Che...

Page 10: ...the label and in these installation instructions 2 Mark the position for the hole for the chimney in the ceiling and roof by using a string and plumb bob 3 Checkthattheintendedlocationwillnotinterfere...

Page 11: ...190712 28 11 26 60 10 77 3 8 38 3 4 109 1 2 77 3 8 27 3 8 50 5 8 50 5 8 61 3 4 50 5 8 1 6 3 8 Minimum Framing Dimensions FIG 10 NOTE THE FRAMING DIMENSIONS AROUND THE FIREPLACE MUST INCLUDE THE INNER...

Page 12: ...7747 FRAMING KIT LEG 3 1 2 L 3 Framing Kit Assembly 2 3 Each Kit Contains Assembly Lay out top bottom studs 2 and center studs 5 on a large flat surface Fig 9 Using the screws provided 1 attach the f...

Page 13: ...PACIFIC FP30 190712 28 13 Minimum Clearances to Combustibles 6 3 8 6 3 8 27 3 8 30 10 9 1 FIG 11...

Page 14: ...rk arrestor rain cap Radiation shield Chimney Support 38 5 978mm Minimum distance from unit to ceiling Minimum 7 2 1m Ceiling Height Non combustible floor protector The chimney may incorporate an offs...

Page 15: ...s adapter and protruding through the roof Avoid having joints between ceiling and roof It is required to secure connections with three 3 12 mm metal screws 5 Installradiationshields firestopsandallpi...

Page 16: ...rers installation instructions 3 Use another elbow to turn the chimney vertically Secure the elbow 4 Use a plumb bob to line up the centre of the hole Cut a hole for the chimney in the ceiling floor F...

Page 17: ...otection as required Attach 4 venting not supplied to adapter WARNING This hole must get its air from the outdoors and be finished with an approved vent cap The use of outside combustion air for resid...

Page 18: ...r the fireplace front and the other half must extend onto the floor and under the hearth extension ember protection as shown in Fig 18 Safety metal strip Cement Board 1 2 minimum if desired Hearth ext...

Page 19: ...EMOTE GRAVITY HEAT DUCT KIT MUST BE INSTALLED WITH THE FP30 PART FP30 GVKIT INSTALLATION 1 Usingapairoftinsnips cutawaythesquaresectionblock ingtheheatductopeningsandcutoutinsulation Fig 20 2 Attach t...

Page 20: ...opening in the wall outlet and secure to the outlet with two 8 X 1 2 Tek screws Cover with outlet screen provided or one of equal outlet area 6 Maintain clearances to combustibles as described in the...

Page 21: ...of the dimensioned area shown by the dotted line in Fig 24 Use the manufactures suggested fasteners to attach the ce ment board and install as recommended Tape and mud the joints as per the board man...

Page 22: ...EL DEPTH B 2 TO 12 MANTEL CLEARANCE CHART 16 1 2 NON COMBUSTIBLE FACING MATERIAL COVERING FROM THE CONVECTION AIR OUT LET TO THE CEILING NON COMBUSTIBLE ZONE DO NOT INSTALL ANY COMBUSTIBLE MATERIAL EL...

Page 23: ...eosote Buildup See 1 2 3 above Low Heat Output 1 Wood is wet Use dry wood 2 Fire too small Build a larger fire 3 Draft too low Chimney plugged or restricted inspect and clean Won t Burn Overnight 1 Ai...

Page 24: ...f this design Traditional wood stoves had a basic combustion system which allowed a considerable amount of heat energy to escape up the chimney as unburned gases and particulates smoke Pacific Energy...

Page 25: ...Baffle not sold separately SUMB BAFF 10b Side Insulation 5068 732 C 11 Brick Rails 2pc Required SUMM RAILSET 12 Baffle Pin SSER 125001 13 Baffle Gasket SUMB 31396 14 Flame Shield c w Bolt and Nut SUM...

Page 26: ...26 PACIFIC FP30 190712 28...

Page 27: ...ES SEE LOCAL BUILDING CODE AND MANUFACTURER S INSTRUCTIONS FOR PRECAUTIONS REQUIRED WHEN PASSING A CHIMNEY THROUGH A COMBUSTIBLE WALL OR CEILING CHIMNEY SYSTEM MUST BE LISTED TO IN CANADA USE ONLY ICC...

Page 28: ...PACIFIC ENERGY FIREPLACE PRODUCTS LTD 2975 Allenby Rd Duncan B C V9L 6V8 Phone 250 748 1184 Web site http www pacificenergy net Printed in Canada...

Reviews: