Fireplace Dimensions
Gas Pressure Testing Procedure
Note: To test the gas pressure, turn off the gas supply to the appliance before loosening
test point screws.
Verify gas pressures with the fireplace lit and at the highest setting.
1. Remove window surround and locate the valve as seen in Figure 32.
2. Locate the inlet and outlet test ports on the valve which can be seen in Figure 33. After
locating test ports loosen the screws within the ports using a flat-tip screwdriver.
3. Attach pressure gauge to the test ports
4. Turn gas supply back on and test pressures.
5. After testing is finished turn off gas supply, remove the pressure gauges and tighten up the
screws in the test points.
Pilot Adjustment
The pilot flame level can be
adjusted by turning the adjustment
screw, using a flat-tip screwdriver,
seen on the valve in Figure 33.
Figure 24: Valve Location
Figure 33: Valve
Figure 32: Valve
VENTURI ADJUSTMENT