Maintenance
Turn off gas and electrical power supply (if applicable) and allow ample time for unit to cool
before servicing appliance. It is recommended that the fireplace and its venting should be
inspected at least once a year by a qualified service person.
Glass Door:
Warning:
Do not operate fireplace with glass door removed, cracked or broken. Replacement of
the glass door should be done by a licensed or qualified service person.
Do not strike or otherwise impact the glass in any way that may cause it to break. If the glass
becomes cracked or broken it must be replaced before using the fireplace. Replacement door can be
obtained from your nearest Pacific Energy dealer.
Do not substitute with any other type.
To remove broken glass, remove Door as noted in "Door Removal" section.
Annual Inspection:
a)
Remove glass door and decorative media (such as logs and rocks). Inspect decorative media
and burner assemblies for soot buildup. If excessive buildup of soot is present, have a
qualified service person inspect and adjust unit for proper combustion. Clean burners with a
brush or vacuum cleaner, paying close attention to burner ports.
b) Check the pilot system for proper flame size and operation. Clean pilot free (Fig 16) of soot,
dust or any other deposits.
Figure 16