7 MAINTENANCE
The TF 2000 is designed to operate with a minimum level of maintenance.
However, replacement of some parts will be required from time to time.
Please follow the maintenance instructions below when replacing parts. If
there are any questions, contact PACE.
CAUTION:
Disconnect the main power supply and computer
cables, if applicable, BEFORE opening the TF 2000B,
TF 2000BE, TF 2000BL, TF 2000BLE, TF 2000R, TF
2000P, BEFORE replacing any component of the TF
2000, and BEFORE performing ANY routine
maintenance.
7-1
Cleaning the Blower Filter
Clean the filter every three (3) months.
1) Take off the cover on the back of the TF 2000R. Please see
Figure 2.
2) Loosen the butterfly screw fitted inside.
3) Remove the filter from the housing.
4) Clean the inside filter using warm water.
5) Make sure the filter is dry before re-assembly.
7-2
Replacing the Top Heater
Please refer to Figure 21 for heater replacement.
1) Disconnect the TF 2000 from
ALL
power supplies.
2) Remove the protective cover from the reflow head by removing
the four screws on the left side.
3) Loosen the two screws in the terminal block that affix the wires
from the top fan.
4) Set the fan aside.
5) Loosen the two bolts on the top of the assembly.
6) Lift off the connectors that secure the wires from the power
indicator lamp on the front of the protective cover.
7) Set the cover aside.
8) Lift off the heater wires from the mounting posts.
9) Remove the terminal block taking out the two screws that
secure it to the assembly.
10) Pull off the rubber hose from the connection on the top of the
assembly.
11) Loosen the three Philips head screws from the sides of the
housing and the hex bolt in the back that secure the top cover
of the assembly