6-2.1 Optics Tab Inspection View
This Screen is used in conjunction with the XR 2000 X-Ray Inspection
System. Real time X-Ray video can be viewed, stored and compared to a
reference library of common faults or desired results.
The Review and Capture Buttons operate the same as in Alignment View. The
Arrow Buttons scroll between images stored in the reference library.
To Add a Reference Image:
Any Image captured as a .bmp file may be
converted to a .tif image using the “Imaging” program (located on the Windows
Accessories Menu) and added to the “XrayLib” folder under the TF 2000
Software directory.