System Operations Manual
www.paceworldwide.com
Page 47 of 50
iii.
In the back, loosen the screw in the center on the back of the camera
housing.
iv. Rotate the camera until the left and right sides of the nozzle are centered
between the sides of the viewing area.
v.
Tighten
the
screws.
4. Component Nest Platform alignment. This adjustment is to align the nest to the nozzle.
a. Loosen the 4 allens on the component nest base plate, the 2 allens on the left
adjustment arm, and the one allen on the mechanical stop.
b. Place the component nest platform on the camera housing.
c. Adjust the component nest all the way open.
d. Click on the pickup button. BE PREPARED TO CLICK ON THE STOP HEATER ARM
BUTTON. You want to stop the nozzle above the nest.
e. Now step the nozzle down using the arrows so the corners of the nozzle are just inside
the corners of the nest where the component would normally be.
f.
Adjust the nest closed and adjust the nest position so the corners of the nest are
contacting the corners of the nozzle, front and back.
g. Tighten the allen screws on the base plate and on the left adjustment.
h. Push the mechanical stop against the bearing sleeve and tight that allen.
i.
Click on home.
Figure
Base Plate
Left adjustment arm
Mechanical stop