xii. If solder ball on part do not line up with holes on test PCB, adjust prism
until it is.
1. Loosen the setscrews from the light adjustment knobs (Figure 14)
2. Remove the knobs
3. Remove the four screws (2 on each side) from the cameras’ sheet metal
cover (Figure 14)
4. Remove the cover
5. Loosening the top screws (A) and tightening the bottom screws (B)
adjusts the prism down. Figure 15
6. Loosening the bottom screws (B) and tightening the top screws (A)
adjusts the prism up.
7. Loosening the right center screw (C) allows you to rotate the prism
around the y-axis.
8. When aligned, replace the cover
9. Replace the four screws
10. Replace the knobs
11. Adjust the light adjustment knobs and tighten the setscrews
xiii. Return to setup screen. Mouse click on button, “Return to Setup.”