8
GENERAL INFORMATION
PARTS IDENTIFICATION
1. POWER SWITCH -
Turns system ON (1) and OFF (0); controls input power to system.
2. CH 1 VARIABLE TEMPERATURE CONTROL -
Allows the operator to adjust the tip temperature
for handpiece/tip combination connected to channel 1.
3. CH 2 VARIABLE TEMPERATURE CONTROL (MBT 201A/J/E Systems Only) -
Allows the
operator to adjust the tip temperature for handpiece/tip combination connected to channel 2.
4. CH 1 POWER RECEPTACLE -
Provides power, tip ground, sensing circuitry and finger switch
connection from MBT system to the handpiece connected to channel 1.
5. CH 2 POWER RECEPTACLE (MBT 201A/J/E Systems Only) -
Provides power, tip ground,
sensing circuitry and finger switch connection from MBT system to the handpiece connected to
channel 2.
6. CH 1 LED -
Green LED provides visual indication of duty cycle control of channel 1. Indicator lights
as power is applied to the connected handpiece.
7. CH 2 LED (MBT 201/J/E Systems Only) -
Green LED provides visual indication of duty cycle
control of channel 2. Indicator lights as power is applied to the connected handpiece.
8. AUTO SNAP-VAC PORT -
Quick connect fitting which provides quick-rise vacuum for Sodr-X-
Tractor or ThermoPik handpieces. Vacuum is present when handpiece finger switch or optional foot
pedal is actuated. Vacuum continues a minimum of 1.2 seconds after switch (or foot pedal) actuation.
9. CONTROLLABLE PRESSURE PORT -
Quick connect fitting with adjustable valve which
provides variable air flow for the Mini ThermoJet handpiece. Air pressure is present when handpiece
finger switch or optional foot pedal is actuated. Air pressure ceases 1.2 seconds after switch (or foot
pedal) is released.
10. EARTH GROUND RECEPTACLE -
Provides positive earth ground to which a ground cable can be
connected from the workpiece or work surface as part of a static control program.
11. POWER CORD -
Provides main power to system from AC outlet to AC Power Receptacle.
12. AC POWER RECEPTACLE/FUSE HOLDER -
Receptacle for providing power to the system from
AC outlet through Power Cord, and location of fuse which protects system from overcurrent
conditions.
13. FUSE -
Provides overload protection for MBT system.
14. FOOT PEDAL RECEPTACLE -
Input for foot pedal (optional) which actuates vacuum or pressure
to the air-operated handpieces.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com