PowerHalt is a registered trademark of Pacbrake Co.
7
PH2 - AUTO / MANUAL / ELECTRIC WITH PULL CABLE(S)
L6372
L6372_REV6.17.04.2018
ECN 1-1859
AUTOMATIC KIT INSTALLATION
13
POWERGUARD INSTALLATION
Locate a suitable location for the PowerGuard controller. It is
recommended that the controller be within a compartment and in
a location that is protected from mechanical damage. A flat
(7" x 7") space is required to mount the controller.
Use 2 self-tapping screws or 2 cap screws (not provided) to
fasten the controller firmly in place.
Connect the wiring harness’ grey and black connectors as per
the wiring schematic provided at the back of this manual to the
PowerGuard controller (see page 11).
NOTE: Ensure the PowerGuard controller is not mounted in
locations that are exposed to high pressure water or locations
which can exceed ambient temperatures of 80°C
14
SWITCH INSTALLATION
Locate a convenient location on the control panel (see photo
14A) to install the PowerHalt shutdown switch. Drill a ½” hole in
the control panel for the switch installation.
Install the toggle switch through the backside of the control
panel and then remove the nameplate cover film and install the
nameplate, the switch cover, the washer, and the nut (see photo
14B and 14C). Torque the nut firmly. Connect the wiring harness
lead with the 2 blue spade connectors to the override switch.
15
POWER INSTALLATION
Route the harness leg with the 15 AMP fuse and Ground wire to
the Engine battery location as per the wiring schematic provided
(see page 11).
Connect to the Power and ground lugs.
NOTE: Secure the wiring harness with the provided tie straps
away from any moving parts or high heat sources.
14A
14B
14C
13A