background image

PowerHalt is a registered trademark of Pacbrake Co.

  10

PH2  - AUTO / MANUAL / ELECTRIC  WITH  PULL  CABLE(S)

L6372

L6372_REV6.17.04.2018

ECN 1-1859

VALVE OPERATION

Prior to running your system you must ensure that the valve is latched (clockwise) into its open position and 

that the above installation procedure was completed as described. It is recommended that the engine be 

shipped with the shut-off valve system in its active/open and ready-to-use state. 
To carry out the emergency shutdown procedure, the pull cable handle must be pulled as this will shut the 

valve and stop the engine. 

CAUTION: No attempt to restart the engine should happen until the activation information/details are 

understood and the valve is confi rmed to be returned back to the open “Run” position.
NOTE: Please reference your specifi c operation procedures defi ned by your organization for additional 

operation specifi cs / details. If you require additional recommendations on the steps to operate your shut-off 

valve, please reference PowerHalt’s operation manual based on your application.

VALVE MAINTENANCE

To ensure a trouble-free long life of your PowerHalt shut-off valve a scheduled maintenance procedure is 

mandatory. It is recommended that you follow the requirements & procedures stated below:

MONTHLY REQUIREMENTS

●  Inspect all clamps, pull cables and support brackets to ensure they are in good condition and to the 

required torque.

●  Inspect all wiring & cable runs to ensure there is no corrosion or wear.

●  Inspect all hoses to ensure there are no cracks or damage.

●  Activate the valve to ensure it is exercised.

See procedure below.

3 MONTH REQUIREMENT

 

(or at oil change interval’s whichever comes fi rst)

●  Lubricate the PH2, fl ap O-ring, with Parker® Super O-Lube, Part # SLUBE 884-2, or equivalent.

VALVE ACTIVATION PROCEDURE:

1

  Run engine at low RPM (preferably at idle).

2

  Activate the PowerHalt shut-off valve by pulling the cable handle. 

The engine should stop within a few seconds.

NOTE: 

●  If the engine does not shutdown in the specifi ed time, please check all intake piping and hoses 

for leaks between the valve and the intake system.

●  If the system is leak free and your valve still does not shut down the engine, please consult 

PowerHalt’s service representative for support.

3

  Once the engine stops, wait 30 seconds, then reset the valve by turning the red reset knob 

clockwise to the open “Run” position with knob arrow in line with air fl ow direction.

CAUTION: The #1 failure mode of any valve in the market is seizing due to lack of use. As this is a safety 

device, it is imperative that you employ safety activation testing at a minimum of once per month.

Summary of Contents for PowerHalt PH2

Page 1: ...SHUT OFF V AL VE AIR INTAKE EMERGENCY SHUT OFF V AL VE PH2AIR INTAKE EMERGENCY SHUT OFFVALVE AUTO MANUAL ELECTRIC WITH PULL CABLE WITH POWERGUARD SMART OVERSPEED LIMITER COMES WITH AUTOMATIC ACTUATION...

Page 2: ...ensure this may result in hose collapse during valve activation and possible system leaks preventing engine shutdown For excessive vibration applications and installations with long pipe runs addition...

Page 3: ...ity Knife Torque Wrench KIT CONTENTS A 1 PH2 Manual Electric with Pull Cable Shut off Valve B 8 Tie Straps C 4 Pre Tension Clamps D 2 Silicone hose E 1 Wiring Harness Automatic Actuation Harness Shown...

Page 4: ...ION Disconnect the battery Remove the engine panels or covers to gain access to the intake hose location where the shut off valve will be installed 2 Remove the stock clamps and hoses from the air cle...

Page 5: ...59 6A 6B 6C 6D 1 2 3 1 4 2 FIGURE 6A 1 T Handle Bulk Head Fitting 2 M10 Nuts 3 M10 Flat Washers 4 M5 Nut 5 T Handle FIGURE 6B 1 Threaded end fitting 2 M8 Pretention adjusting nuts 3 M8 Flat washers 4...

Page 6: ...nd washer on either side of the bracket see photo 7C For valves with dual pull cables repeat steps 7 8 Cable pretension is achieved when the T handle M5 jamb nut is just being pulled against threaded...

Page 7: ...ngle dash wall for install unless the double wall is modified DO NOT ACTIVATE THE MANUAL SWITCH FOR MORE THAN 10 SECONDS Damage to the solenoid may occur 10 Drill a hole in the desired location 11 Ins...

Page 8: ...n locations that are exposed to high pressure water or locations which can exceed ambient temperatures of 80 C 14 SWITCH INSTALLATION Locate a convenient location on the control panel see photo 14A to...

Page 9: ...5 8 18 is 20 ft lbs Magnetic pick up diameter 3 4 16 is 62 ft lbs Install the provided magnetic pick up mag into the new tapped hole on the Bell Housing Thread in all the way until the mag contacts th...

Page 10: ...tion This will have the line direction on the reset knob perpendicular from the air flow direction 3 Reset the valve 4 Activate both pull cable stations 5 Reset valve 6 Start the engine and run 7 Acti...

Page 11: ...ded that you follow the requirements procedures stated below MONTHLY REQUIREMENTS Inspect all clamps pull cables and support brackets to ensure they are in good condition and to the required torque In...

Page 12: ...e shut off speed prior to proceeding 1 With the engine idling hold down the SET and TEST buttons simultaneously until both lights begin to ash approximately 5 seconds then release the buttons 2 Press...

Page 13: ...the engine failed to shut down check for leaks in the piping and consult a PowerHalt representative ERASING THE EXISTING EMERGENCY ENGINE SHUTOFF SPEED 1 Hold both SET and TEST buttons simultaneously...

Page 14: ...To Customer Connection TOGGLE SWITCH To Mag Pickup Sensor Connection TO MICRO SWITCH To Customer Connection 15A FUSE 5A FUSE BATTERY Micro switch may or may not be included depending on application M...

Reviews: