PowerHalt is a registered trademark of Pacbrake Co.
5
PH2 - AUTO / MANUAL / ELECTRIC WITH PULL CABLE(S)
L6372
L6372_REV6.17.04.2018
ECN 1-1859
7B
7C
8B
INCORRECT
CORRECT
8A
7
Insert the Cable ball end into the activation pin. (See photo 7A)
Install the Coupling sleeve over the activation pin, align the slot
to allow the cable to pass through the coupling sleeve.
NOTE: One end of the coupling sleeve has a counter bore, this
end must go towards the activation pin.
(See photo 7B)
Rotate the cable 90°, and insert the threaded end fitting into the
slot on the attaching bracket, with one M10 nut and washer on
either side of the bracket. (see photo 7C)
For valves with dual pull cables, repeat steps 7.
8
Cable pretension is achieved when the T-handle M5 jamb nut is
just being pulled against threaded end of the bulkhead fitting.
Adjust the threaded end fitting, M8 adjusting nut, with a two M14
wrenches to ensure the cable pretension is correct.
NOTE: The Coupling sleeve must be held from moving, this is
achieved with proper adjustment of the threaded end fitting.
Torque adjusting nuts to 11 +/- 1 ft-lbs (15 +/- 1.3 N•m).
Torque the nuts of the threaded end fitting to the valve bracket to
9 +/- 1 ft-lbs (12 +/- 1.3 N•m). Installed in step 7.
NOTE: Secure the pull cable with the provided tie straps, away
from any moving parts or high heat sources.
NOTE: A MINIMUM BEND RADIUS OF 4" MUST BE MAINTAINED.
7A