WARNING!
•
If any of the LEDs lights up in red, contact your local vendor to request a replacement
immediately.
•
When removing the PSU/Cooling Module, pull the module for about 3 inches then wait for
at least 10 seconds before removing the whole module from the enclosure.
•
DO NOT run the system with faulty PSU/Cooling Module(s) as it may cause disruption of
the airflow resulting in overheating.
CAUTION!
Keep your body away from the moving parts of the system.
Super Capacitor and Flash Backup Module (FBM)
The PS 2000 Series system also has a Cache Backup Module (CBM), which is comprised of a
super capacitor and Flash Backup Module (FBM), installed in the controller. The super capacitor
stores cached data to the flash backup module permanently in case of power interruption or
outage.
NOTE:
The super capacitor is partially charged when shipped. When you turn the system ON, the
super capacitor will charge to its full capacity for a few minutes. If it is not charging, there may be
a problem. Contact your system vendor immediately. You can also check the status of the super
capacitor via the PAC Management Software or the firmware. Refer to the manuals for more
details.