19
PSU/Cooling Module
The PS 2000 Series system has two redundant hot-swappable PSU/cooling modules that
provide power and help with the airflow, providing an efficient ventilation.
Number Part
Extraction lever
Retention screw
Power socket
Power switch
PSU status LED
Fan
When the cooling modules operate under normal conditions, the cooling fans run at a low
speed. The cooling fans raise their rotation speed to increase the airflow under the following
conditions:
•
Component failure: If the cooling module, PSU, or temperature failed.
•
Elevated temperature: If the temperature breaches the upper threshold set for any of the
interior temperature sensors.
During the initialization stage, the cooling fans operate at a high speed. The speed is lowered
when the initialization is complete and no errors are detected.
NOTES:
•
The PSU/Cooling Modules have specific installation orientations for left and right slots.
Refer to the label on the back of the system.
•
There are two upper temperature thresholds: one for event notification and the other for
triggering high fan rotation speed. You can change the preset values for event notification
using the firmware – embedded configuration utility. Refer to the firmware operation
manual for details.