1

  3. INSTALLATION

Connecting the Discharge Outlet

1.    Insert  a  hose 

adaptor and an 

o-ring into one of 

the collars.

2.   Screw the hose adaptor and 

collar tightly onto one of the 

pump outlets in a clockwise 

direction to secure in place.

Note:  

Teflon tape (not supplied) 

is recommended on 

threads to ensure a water 

tight seal and prevent any 

leakage.

3.   Repeat this process to fit multiple outlets.

 

Ensure unused outlets are fitted with the supplied outlet caps 

to stop water from expelling out of the discharge outlets.

The outlet allows for a 25.4mm (1”) and 40mm (1½”) pipe to be 

connected and is capable of a maximum head of 70m.

The pump has 3 outlets (2x 25.4mm and 1x 40mm), 

which allows for multiple outlets to be used to pump water 

simultaneously, however this will result in lower pressure and 

flow rate.

  2.  CONNECTING THE OUTLET

NOTE: 

TO USE THE PUMP IN PERMANENT INSTALLATIONS 

WITH RIGID PIPES, INSTALL A NON-RETURN VALVE TO AVOID 

THE FLUID BEING RE-CIRCULATED ONCE THE PUMP HAS 

STOPPED.

CAUTION:

 

ALL CONNECTIONS MUST BE AIR TIGHT, 

FAILURE TO DO SO MAY RESULT IN AN AIR LEAK 

WHICH CAN PREVENT THE PUMP FROM PRIMING.

1.  Ensure the pump is mounted to a rigid base or ground.

70m

7m

MAXIMUM DELIVERY HEIGHT

WATER LEVEL

CAUTION:

 

ALWAYS CARRY OR LIFT THE PUMP BY THE 

FRAME TO AVOID DAMAGING THE UNIT.

CAUTION:

 

THIS PRODUCT IS INTENDED FOR PUMPING 

WATER IN A HOME DOMESTIC APPLICATION. DO NOT 

USE IT FOR CORROSIVE, ABRASIVE, EXPLOSIVE OR 

DANGEROUS LIQUIDS.

2.   Ensure the distance from the surface of the water to the 

pump inlet does not exceed 7m.

3.   Ensure the distance from the pump to the highest point that 

you wish to deliver the water does not exceed 70 metres.

Before starting, perform a few simple checks:

WARNING!

 

ENSURE THE OUTLET FOR THIS PUMP, INCLUDING 

ANY HOSES OR PIPES ARE NOT RESTRICTED OR OBSTRUCTED 
IN ANY WAY. TAPS, VALVES AND ANY TYPE OF TRIGGER 
NOZZLE MUST NEVER BE USED WITH THIS PUMP. FAILURE TO 
FOLLOW THESE INSTRUCTIONS MAY RESULT IN PUMP FAILURE 
OR SERIOUS INJURY.

Summary of Contents for PFFP-65E

Page 1: ...R SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE WARRANTY POLICY OR PROCEDURE OZITO Australia New Zealand Head Office 1 23 Letcon Drive Bangholme Victoria Australia 3175 The benefits provided under this warranty are in addition to other rights and remedies which are available to you at law Our goods come with guarantees that cannot be excluded at l...

Page 2: ...ted and is capable of a maximum suction height of 7m The pump inlet and outlets have been fitted with a protection cover for transportation These will need to be removed before connecting any pipes CAUTION AVOID POSITIONING THE INLET PIPE HIGHER THAN THE PUMP AS THIS WOULD DELAY THE ESCAPE OF AIR BUBBLES FROM THE INLET PIPE CAUTION THE INPUT HOSE OR PIPE SHOULD BE LOW ENOUGH IN THE WATER TO ENSURE...

Page 3: ...PES INSTALL A NON RETURN VALVE TO AVOID THE FLUID BEING RE CIRCULATED ONCE THE PUMP HAS STOPPED CAUTION ALL CONNECTIONS MUST BE AIR TIGHT FAILURE TO DO SO MAY RESULT IN AN AIR LEAK WHICH CAN PREVENT THE PUMP FROM PRIMING 1 Ensure the pump is mounted to a rigid base or ground 70m 7m MAXIMUM DELIVERY HEIGHT WATER LEVEL CAUTION ALWAYS CARRY OR LIFT THE PUMP BY THE FRAME TO AVOID DAMAGING THE UNIT CAU...

Page 4: ...wise 1 Remove the oil fill plug from the side of the engine Clean the dip stick and re insert without screwing down 3 Place the fuel cap back on and clean up any spillage Priming the pump prepares the motor for safe operation Only use unleaded 91 RON Research Octane Number petrol Purchase fuel in quantities that can be used every 30 days to prevent gum or foaming inside the container and or fuel t...

Page 5: ...arter rapidly Allow the rope to rewind slowly and if necessary repeat this procedure until the engine starts Air Filter Starting the Engine Stopping the Engine Spark Plugs 1 Ensure the filter is free from any debris 2 If necessary clean or replace the filter by following the steps outlined in the maintenance section of this manual 2 To remove and install the spark plug refer to the maintenance sec...

Page 6: ...e spark plug lead 3 Insert the filter and secure with the filter cover and nut 3 Clean the electrode with a metal brush and remove any carbon build up or replace the spark plug Turn the drain screw anti clockwise and remove from the pump body to allow excess water to drain out Ensure that the drain screw is fitted once all water has drained out 2 Remove the cover and the air filter Check that the ...

Page 7: ...cessary Increase throttle Unit will not start No fuel Fuel valve in off position Oil level too low Low quality or deteriorated old fuel Dirty muffler exhaust Choke adjusted incorrectly Air filter clogged Fuel evaporation in carburettor vapour lock due to high temperatures Spark plug is wet or the spark plug electrode is dirty placed inadequately or is faulty Fill engine fuel tank Refer to engine o...

Page 8: ...his appliance is not intended for use by person including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Ensure the water pump is switched o...