background image

1

Spare parts can be ordered from the Special Orders Desk 

at your local Bunnings Warehouse. 
For further information, or any parts not listed here, visit 
www.ozito.com.au or contact Ozito Customer Service: 
Australia 1800 069 486 New Zealand 0508 069 486 
E-mail: [email protected]

 GENERAL POWER TOOL SAFETY WARNINGS

 ADDITIONAL SAFETY WARNINGS FOR PUMPS

DESCRIPTION OF SYMBOLS

ORDERING REPLACEMENT PARTS

FLOW CURVE

WARNING!

 

Read all safety warnings and all instructions. 

Failure to follow the warnings and 

instructions may result in electric shock, fire and/or serious injury. 

 

Save these instructions

1. Work area safety 

a.  

 Keep work area clean and well lit

. Cluttered or dark areas invite accidents. 

b.  

Donotoperatepumpsinexplosiveatmospheres,suchasinthepresenceofflammableliquids,

gases or dust.

 Pumps create sparks which may ignite the dust or fumes. 

c.  

 Keep children and bystanders away while operating a pump.

 Distractions can cause you to lose control.\

2. Personal safety 

a.  

 Stay alert, watch what you are doing and use common sense when operating a pump. Do not use 

apumpwhileyouaretiredorundertheinfluenceofdrugs,alcoholormedication.

 A moment of 

inattention while operating a pump may result in serious personal injury. 

b.  

 Avoid accidental starting. 

Carrying pump with your finger on the recoil starter invites accidents.

3. Pump use and care 

a.  

 Store idle pump out reach of children and other untrained persons.

 Pumps are dangerous in the hands 

of untrained users.

b.  

 Always shut off the engine, allow the engine to cool and remove spark plug before making any 

adjustments, changing accessories,or storing pumps.

 Such preventive safety measures reduce the risk 

of starting the pump accidentally. 

c.    

Maintain pumps. Check for misalignment or binding of moving parts, breakage of parts and any other 

condition that may affect the pumps operation. If damaged, have the pump repaired before use.

 Many 

accidents are caused by poorly maintained pumps. 

d.    

Use the pump, and accessories etc., in accordance with these instructions and in the manner 

intended for the particular type of pump, taking into account the working conditions and the work to 

be performed.

 Use of the pump for operations different from intended could result in a hazardous situation. 

4. Service 

a.  

Haveyourpumpservicedbyaqualifiedrepairpersonusingonlyidenticalreplacementparts.

This will 

ensure that the safety of the pump is maintained.

WARNING! 

This product is intended for pumping water in a Home Domestic application. Do 

not use it for corrosive, abrasive, explosive or dangerous liquids. Fluids other than water will 

damagethewaterpumpand/orcreateafirehazard.Failuretofollowallinstructionslisted

belowmayresultinelectricshock,fireand/orseriousinjury.

WARNING!

 This product is not suitable for use with drinking (potable) water.

This appliance is not intended for use by person (including children) with reduced physical, sensory or 

mental capabilities, or lack of experience and knowledge, unless they have been given supervision or 

instruction concerning use of the appliance by a person responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

•  Ensure the water pump is switched off when installing.

• 

Donotinstalloroperatethewaterpumpinanexplosiveenvironmentornearflammablematerial.

•  Do not operate the water pump without liquid.

•  Do not run the water pump dry.

•   Never refuel while engine is running or hot.

 Fuel spilled on a hot engine could result in a fire or explosion.

• 

Usecautionwhenhandlingpetrol.Refuelinwell-ventilatedarea.Donotoverfillfueltankanddonot

spill fuel. Make sure tank cap is closed properly

. Petrol is extremely flammable and is explosive under 

certain conditions.

• 

Neverruntheengineinanenclosedorconfinedarea.

 Exhaust contains poisonous carbon monoxide gas; 

exposure may cause loss of consciousness and may lead to death.

• 

Donotusetopumpflammableorexplosiveliquidssuchasgasoline,fueloil,kerosene,solventsor

thinners. Pump should only be used with liquids compatible with pump component materials. 

Failure 

to follow to this warning can result in serious personal injury, death and/or property damage.

•   Pump must be located on a solid level surface.

 Pump could tip or fall causing serious injury.

•   Do not hold or suspend pump by means of a discharge pipe.

 Pipe could break or come loose.

• 

Becarefulnottotouchthemufflerwhileitishot.Toavoidsevereburnsorfirehazards,letthe

 

engine cool before transporting or storing it indoors. 

The muffler becomes very hot during operation and 

remains hot for a while after stopping the engine. Exhaust may contain chemicals that may cause cancer or 

reproductive harm.

WARNING!

 The water pump together with associated pipework operate under pressure. Do not 

disconnect water pump or pipework until internal pressure has been released. Failure to do this 

could result in personal injury and damage to property.

•  Avoid inserting hands into the inlets/outlets of the water pump while it is operating.
• 

Before using the water pump, always inspect it visually. Do not use the pump if it is cracked and/or damaged.  

If the water pump is damaged, contact Ozito customer service.

•  The pump must not be used when people are in the water.
•  Pollution of the liquid could occur due to leakage of lubricants

  

V

 

    

Volts

 

 

 

 

Hz

 

    

Hertz

  

~

 

    

Alternating current

 

 

W

 

    

Watts

/min

      

Revolutions or 

 

    reciprocation per minute

 Hp

      

Horse power 

 

 

 ˚C

          

Degrees Celsius

   

p/hr

      

Per hour 

 

 

  

kPa

        

Pressure rating (kilopascals)

        

 bar

      Pressure rating   

             

L

  

         

Litres     

  

F

 

    Insulation class   

          

PVC

        

Polyvinyl chloride     

 

 

n

o      

No load speed

Regulator compliance mark

Warning

Read instruction manual

IPX8

       

Ingress protection from water

cc

Cubic centimeters

Fire

Toxic fumes

Hot surface

0

10

20

30

40

50

60

70

80

0

2000

4000

6000

8000

10000

12000

14000

Head Height ( m )

Flow Rate ( I/hour )

PFFP-65E Pump Flow Curve

Summary of Contents for PFFP-65E

Page 1: ...R SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE WARRANTY POLICY OR PROCEDURE OZITO Australia New Zealand Head Office 1 23 Letcon Drive Bangholme Victoria Australia 3175 The benefits provided under this warranty are in addition to other rights and remedies which are available to you at law Our goods come with guarantees that cannot be excluded at l...

Page 2: ...ted and is capable of a maximum suction height of 7m The pump inlet and outlets have been fitted with a protection cover for transportation These will need to be removed before connecting any pipes CAUTION AVOID POSITIONING THE INLET PIPE HIGHER THAN THE PUMP AS THIS WOULD DELAY THE ESCAPE OF AIR BUBBLES FROM THE INLET PIPE CAUTION THE INPUT HOSE OR PIPE SHOULD BE LOW ENOUGH IN THE WATER TO ENSURE...

Page 3: ...PES INSTALL A NON RETURN VALVE TO AVOID THE FLUID BEING RE CIRCULATED ONCE THE PUMP HAS STOPPED CAUTION ALL CONNECTIONS MUST BE AIR TIGHT FAILURE TO DO SO MAY RESULT IN AN AIR LEAK WHICH CAN PREVENT THE PUMP FROM PRIMING 1 Ensure the pump is mounted to a rigid base or ground 70m 7m MAXIMUM DELIVERY HEIGHT WATER LEVEL CAUTION ALWAYS CARRY OR LIFT THE PUMP BY THE FRAME TO AVOID DAMAGING THE UNIT CAU...

Page 4: ...wise 1 Remove the oil fill plug from the side of the engine Clean the dip stick and re insert without screwing down 3 Place the fuel cap back on and clean up any spillage Priming the pump prepares the motor for safe operation Only use unleaded 91 RON Research Octane Number petrol Purchase fuel in quantities that can be used every 30 days to prevent gum or foaming inside the container and or fuel t...

Page 5: ...arter rapidly Allow the rope to rewind slowly and if necessary repeat this procedure until the engine starts Air Filter Starting the Engine Stopping the Engine Spark Plugs 1 Ensure the filter is free from any debris 2 If necessary clean or replace the filter by following the steps outlined in the maintenance section of this manual 2 To remove and install the spark plug refer to the maintenance sec...

Page 6: ...e spark plug lead 3 Insert the filter and secure with the filter cover and nut 3 Clean the electrode with a metal brush and remove any carbon build up or replace the spark plug Turn the drain screw anti clockwise and remove from the pump body to allow excess water to drain out Ensure that the drain screw is fitted once all water has drained out 2 Remove the cover and the air filter Check that the ...

Page 7: ...cessary Increase throttle Unit will not start No fuel Fuel valve in off position Oil level too low Low quality or deteriorated old fuel Dirty muffler exhaust Choke adjusted incorrectly Air filter clogged Fuel evaporation in carburettor vapour lock due to high temperatures Spark plug is wet or the spark plug electrode is dirty placed inadequately or is faulty Fill engine fuel tank Refer to engine o...

Page 8: ...his appliance is not intended for use by person including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Ensure the water pump is switched o...

Reviews: