1

PFFP-65E

  7.  STARTING & STOPPING ENGINE

  6. PRE-OPERATION INSPECTION

1.   Move the choke 

to the left (closed 

position) and the 

fuel lever to the right 

(open position).

1.   Decrease the speed 

of the engine by 

moving the throttle 

to the left 

 and 

allow to idle for 10-20 

seconds.

2.   Move the throttle lever 

to the right 

 (fast 

position).

2.   Move the fuel lever to the 

left (closed position).

Note: 

 Allow the engine to cool 

down before moving or 

storing the pump.

4.   Once started move the 

choke lever to the right 

(open position) and the 

throttle lever to the left 

 (slow position) and 

allow to idle for 3 minutes.

3.   Grip the recoil starter 

and slowly pull until 

resistance is felt, 

then pull the recoil 

starter rapidly. 

Allow the rope to 

rewind slowly and 

if necessary, repeat 

this procedure until 

the engine starts.

Air Filter

Starting the Engine

Stopping the Engine

Spark Plugs

1.   Ensure the filter 

is free from any 

debris.

2.   If necessary clean or replace the filter by following the steps 

outlined in the maintenance section of this manual.

2.   To remove and install the spark plug refer to the 

maintenance section of this manual.

1.   Make sure the electrode 

is clean and the air gap 

is correct (refer to the 

specs of the spark plug 

manufacture).

The air filter must always be in perfect working order, to 

prevent debris and dust from being sucked into the engine thus 

reducing the efficiency and life of the machine.

Use only the spark plugs that are recommended for this petrol 

pump: Champion RC12YC. 

Note:  

Using a spark plug other than that specified could lead to 

serious engine damage.

Summary of Contents for PFFP-65E

Page 1: ...R SERVICE REPRESENTATIVE WILL TAKE YOUR CALL AND ANSWER ANY QUESTIONS YOU MAY HAVE RELATING TO THE WARRANTY POLICY OR PROCEDURE OZITO Australia New Zealand Head Office 1 23 Letcon Drive Bangholme Victoria Australia 3175 The benefits provided under this warranty are in addition to other rights and remedies which are available to you at law Our goods come with guarantees that cannot be excluded at l...

Page 2: ...ted and is capable of a maximum suction height of 7m The pump inlet and outlets have been fitted with a protection cover for transportation These will need to be removed before connecting any pipes CAUTION AVOID POSITIONING THE INLET PIPE HIGHER THAN THE PUMP AS THIS WOULD DELAY THE ESCAPE OF AIR BUBBLES FROM THE INLET PIPE CAUTION THE INPUT HOSE OR PIPE SHOULD BE LOW ENOUGH IN THE WATER TO ENSURE...

Page 3: ...PES INSTALL A NON RETURN VALVE TO AVOID THE FLUID BEING RE CIRCULATED ONCE THE PUMP HAS STOPPED CAUTION ALL CONNECTIONS MUST BE AIR TIGHT FAILURE TO DO SO MAY RESULT IN AN AIR LEAK WHICH CAN PREVENT THE PUMP FROM PRIMING 1 Ensure the pump is mounted to a rigid base or ground 70m 7m MAXIMUM DELIVERY HEIGHT WATER LEVEL CAUTION ALWAYS CARRY OR LIFT THE PUMP BY THE FRAME TO AVOID DAMAGING THE UNIT CAU...

Page 4: ...wise 1 Remove the oil fill plug from the side of the engine Clean the dip stick and re insert without screwing down 3 Place the fuel cap back on and clean up any spillage Priming the pump prepares the motor for safe operation Only use unleaded 91 RON Research Octane Number petrol Purchase fuel in quantities that can be used every 30 days to prevent gum or foaming inside the container and or fuel t...

Page 5: ...arter rapidly Allow the rope to rewind slowly and if necessary repeat this procedure until the engine starts Air Filter Starting the Engine Stopping the Engine Spark Plugs 1 Ensure the filter is free from any debris 2 If necessary clean or replace the filter by following the steps outlined in the maintenance section of this manual 2 To remove and install the spark plug refer to the maintenance sec...

Page 6: ...e spark plug lead 3 Insert the filter and secure with the filter cover and nut 3 Clean the electrode with a metal brush and remove any carbon build up or replace the spark plug Turn the drain screw anti clockwise and remove from the pump body to allow excess water to drain out Ensure that the drain screw is fitted once all water has drained out 2 Remove the cover and the air filter Check that the ...

Page 7: ...cessary Increase throttle Unit will not start No fuel Fuel valve in off position Oil level too low Low quality or deteriorated old fuel Dirty muffler exhaust Choke adjusted incorrectly Air filter clogged Fuel evaporation in carburettor vapour lock due to high temperatures Spark plug is wet or the spark plug electrode is dirty placed inadequately or is faulty Fill engine fuel tank Refer to engine o...

Page 8: ...his appliance is not intended for use by person including children with reduced physical sensory or mental capabilities or lack of experience and knowledge unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety Children should be supervised to ensure that they do not play with the appliance Ensure the water pump is switched o...

Reviews: