background image

6.  PLACEMENT

7.  CONTROLS

The product may only be placed on a flat surface. To provide added 

stability screw the product to a concrete floor with the proper fixation 

materials including bolts, screws and washers.

1.   Disengage the locating pins 

by pulling out on the control 

handle away from the locking 

plate to allow the drum to 

rotate. 

The drum can be set 

at different position to 

cater for mixing mortar 

and concrete, emptying 

or storing.

 The Support Leg has two 

mounting holes that can be used 

to ensure sufficient stability. Use 

two screws or bolts (not included, 

recommended size M10 ) to secure.

ON

OFF

Mortar

Concrete

Unload

Storage

ON

OFF

Mortar

Concrete

Unload

Storage

3.   Engage the control handle 

locating pins to secure the 

position.

Drip Loop

To avoid the possibility of the appliance plug or power point getting wet, 

the user should arrange a “drip loop” in the cord connecting the cement 

mixer to a wall mounted power point.

The “drip loop” is the part of the cord that sits below the level of the 

power point (or the connector if an extension cord is used). It prevents 

water travelling along the cord and coming in contact with the power 

point.

CMX-125U

WARNING!

 

DO NOT PLACE ANY MATERIAL UNDER THE 

PRODUCT TO ADJUST THE HEIGHT OR TO ATTEMPT 

TO IMPROVE ITS STABILITY! IF THE PRODUCT IS ON 

AN ANGLE AND/OR WOBBLY, MOVE IT TO A DIFFERENT 

LOCATION. NEVER OPERATE THE PRODUCT ON SOFT 

SURFACES SUCH AS A LAWN OR GRAVEL SINCE IT 

COULD SINK OR TIP OVER DURING OPERATION!

CAUTION!

 

TO REDUCE THE RISK OF ELECTRICAL 

SHOCK, THE USE OF A RESIDUAL CURRENT DEVICE 

(RATED 30mA OR LESS) IS RECOMMENDED.

OPERATION

Setting the Operating Position

2.   Rotate the drum to the desired 

position by aligning the 

locating pin with two of the 

holes in the locking plate.

ON

OFF

Mortar

Concrete

Unload

Storage

Turning the Mixer On and Off

ON

OFF

Mortar

Concrete

Unload

Storage

1.    To start the mixer press the green 

on “I” button.

2.    To stop the mixer press the red off 

“O”  button..

ON

OFF

Mortar

Concrete

Unload

Storage

WARNING!

 

HOLD THE CONTROL HANDLE TIGHTLY 

WHILE TURNING IT.

Summary of Contents for CMX-125U

Page 1: ...overed by our guarantee Damage to the device caused by a failure to follow the assembly instructions or due to incorrect installation a failure to follow the operating instructions for example connecting it to an incorrect mains voltage or current type or a failure to follow the maintenance and safety instructions or by exposing the device to abnormal environmental conditions or by lack of care an...

Page 2: ... 3 large washer onto axle of the wheel frame secure the assembly with split pin Repeat assembly for other wheel 4 Insert the M8x65 hex bolts with washer through the 2 holes from one side and the M8x55 hex bolt with washer through the end hole of the support leg and secure with nut 2 x 3 x 1 Use assembly fasteners bag 3 Align and insert wheel assembly and support leg into the frame Spanners 13 14 1...

Page 3: ... supplied 7 Insert the M8x20 bolts spring washers and flat washers into each of the mounting holes in the rim Secure each bolt with 14mm spanner not supplied 2 Insert 2 M8x20 bolts and washers into the upper and lower drum from the outside Place the rubber washer thin washer onto the bolt followed by the end of the mixing blade and secure with thin washer and nut 2 4 2 2 2 6 4 M8 55 M8 65 M8 60 M8...

Page 4: ...is as a lever to compress the spring against the large shaft 1 Use assembly fasteners bag 1 Use assembly fasteners bag 4 Use assembly fasteners bag 3 Insert the 2 M8x30 hex bolts spring washers and washers Secure with nut from rear of bearing bracket Tighten with 13 14mm spanners not supplied 2 2 2 6 4 M8 60 M8 20 M8 20 M8 30 M8 20 1 M10 70 2 4 M8 16 1 1 2 M8 25 4 4 4 8 Bolt Spring M8 x 25 M8 x 20...

Page 5: ...int The drip loop is the part of the cord that sits below the level of the power point or the connector if an extension cord is used It prevents water travelling along the cord and coming in contact with the power point CMX 125U WARNING DO NOT PLACE ANY MATERIAL UNDER THE PRODUCT TO ADJUST THE HEIGHT OR TO ATTEMPT TO IMPROVE ITS STABILITY IF THE PRODUCT IS ON AN ANGLE AND OR WOBBLY MOVE IT TO A DI...

Page 6: ...n of the mixer enables the DRUM ASSEMBLY ONLY to be hosed down safely Avoid getting water on the motor and motor housing DO NOT wet the motor and motor housing General Maintenance Ball bearings are packed with grease at the factory No further lubrication of bearings is required During normal use painted surfaces can lose their coating during the mixing process Wipe all exposed surfaces regularly w...

Page 7: ...ce e g Generator has too low voltage Connect to another power source Mixing volume is too large Reduce the amount of material Unsatisfactory result Mixer blades are dull damaged Replace with new ones Mixer blades not suitable for work piece material Use proper mixing blades Excessive vibration or noise Mixer blades are dull damaged Replace with new ones Bolts nuts are loose Tighten bolts nuts Spar...

Page 8: ...off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power tools with your finger on the switch or energising power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turning the power tool on A wrench or a key left attached to a rotating part of the power tool may result in personal injury e Do not ove...

Page 9: ...er Washer Mixing Blades Consumables Missing parts Not necessarily included in the scope of delivery In the effect of defects or faults please register the problem on the internet at www isc gmbh info Plea se ensure that you provide a precise description of the problem and answer the following questions in all cases Did the equipment work at all or was it defective from the beginning Did you notice...

Page 10: ...gree of protection IP44 Sound and vibration Sound and vibration values were measured in accordance with EN 11688 LpA sound pressure level 79 dB A KpA uncertainty 3 dB LWA sound power level 96 dB A KWA uncertainty 3 dB Wear ear muffs The impact of noise can cause damage to hearing Total vibration values vector sum of three directions determined in accordance with EN 11688 Keep the noise emissions a...