background image

Attaching The Support Foot

1.  Place the supporting foot and then a small 

washer onto the small bolt. Thread this 

through the hole in the foot bracket.

2.  Thread the other small washer and then 

the spring washer onto the bolt. Secure the 

assembly with the small nut.

Attaching The Wheels

1.  Place the large bolt through 

the wheel and a large 

washer. Then slide this 

through the hole in the 

wheel bracket. Place a large 

washer then a spring washer 

onto the bolt and secure this 

with a large nut.

2.  Repeat step 1 to fit the second wheel on the opposite side of the 

tank. 

Connecting An Air Hose to the Compressor

1.   Pull back the sleeve on the 

regulated pressure outlet of 

the compressor and insert 

the male Nitto end of the air 

hose..

2.  Release the sleeve; the Nitto 

coupling should click into 

place.

3.  Check that the fitting is secure by tugging gently on the 

connector. If the hose detaches, repeat steps 2 & 3, pushing the 

Nitto connector firmly into the outlet.

Disconnecting Air Tools

1.  To remove an air tool from the unit, retract the sleeve on the 

female Nitto fitting and disconnect the air hose from the air 

compressor.

2.  Repeat the same procedure 

with the air tool and air 

hose.

0

25

50

75

100

12

5

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

AIR COMPRESSOR

2.5HP 40L 

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

AIR COMPRESSOR

2.5HP 40L 

WARNING! 

ENSURE YOU HAVE A FIRM GRIP ON THE 

AIR HOSE WHEN CONNECTING/DISCONNECTING IT 

FROM THE AIR COMPRESSOR, AS PRESSURISED AIR 

IN THE TANK MAY CAUSE IT TO WHIP AROUND AND 

INFLICT INJURY OR DAMAGE.

Summary of Contents for 40L 2.5HP

Page 1: ... If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY Ozito Industries Pty Ltd 25 Fox Drive Dandenong South Victoria Australia 3175 ozito com au 40L Air Compressor 2 x Wheels 2 x Large Bolts 4 x Large Washers 2 x Large Spring Washers 2 x Large Nuts 2 x Support Feet 2 x Small Bolts 4 x Washers 2 x Spring Washers 2 x Nuts 1021 IN ORDER TO MAK...

Page 2: ...ks Examine the machine for signs of transit damage If damaged do not use return to place of purchase The compressor should be set up near to the user Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust free Do not set up the compressor in damp or wet rooms The compressor is designed to be used in dry rooms It is prohibited to use the compressor in areas w...

Page 3: ...is secure by tugging gently on the connector If the hose detaches repeat steps 2 3 pushing the Nitto connector firmly into the outlet Disconnecting Air Tools 1 To remove an air tool from the unit retract the sleeve on the female Nitto fitting and disconnect the air hose from the air compressor 2 Repeat the same procedure with the air tool and air hose 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00...

Page 4: ...an attached blow gun to release some of the pressure until the tank pressure gauge drops below 6bar If the motor does not automatically start up the unit has overloaded and the thermal protection has activated If the thermal protection activates switch off the compressor and allow the compressor to cool down for 15 minutes before restarting WARNING ALLOW THE AIR COMPRESSOR TO COOL BEFORE ATTEMPTIN...

Page 5: ...0 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm AIR COMPRESSOR 2 0HP 40L 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kP...

Page 6: ... PSI kPA BAR PRESSURE GAUGE kg cm AIR COMPRESSOR 2 5HP 40L Symptom Possible Cause Suggested Solution The compressor does not start Compressor has reached cut out pressure Compressor will automatically start once below the cut in pressure No power supply Check the power supply the power plug and the socket outlet Insufficient supply power Reduce length of extension lead Outside temperature is too l...

Page 7: ...g of the tool WARNING BEFORE CLEANING THE APPLIANCE OR CARRYING OUT ANY MAINTENANCE PROCEDURE MAKE SURE THAT IT IS DISCONNECTED FROM THE POWER SUPPLY TO PREVENT ACCIDENTAL STARTING Sound Power Level Wear hearing protection Warning Regulatory Compliance Mark RCM V Volts Hz W Hertz n0 min Alternating Current Watts No load speed Revolutions or reciprocations per minute Read Instruction Manual Beware ...

Page 8: ...t including safety goggles or shield ear protection breathing or respirator mask and protective clothing Never apply the outlet air of this compressor directly on to any part of a person s body Do not attempt to block the air outlet with your finger or any part of your body The tool must be used only for its prescribed purpose Any use other than those mentioned in this Manual will be considered a ...

Reviews: