background image

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

0

25

50

75

100

125

150

0

(1)00

(3)00

(5)00

(7)00

(9)00

2

4

6

8

10

Lb/in²

(PSI)

kPA

(BAR)

PRESSURE GAUGE

kg/cm²

AIR COMPRESSOR

2.0HP 40L 

1.  Motor

2.  On/Off Switch

3.  Pressure Regulator

4.  Carry Handle

5.  Regulated Pressure Outlet

6.  Regulated Pressure Gauge

7.  Support Foot

8.  Drain Valve

9.  Pressure Tank

10. Wheel

11. Tank Handle

12. Tank Pressure Gauge

AIR COMPRESSOR

KNOW YOUR PRODUCT

1. ASSEMBLY

SETUP & PREPARATION

1

2

3

4

5

6

7

8

10

11

9

12

ONLINE MANUAL

Scan this QR Code with your mobile 

device to take you to the online manual.

Pre-Setup Checks

•   Examine the machine for signs of transit damage. If damaged, 

do not use, return to place of purchase 

•   The compressor should be set up near to the user.

•   Avoid long air lines and long supply lines (extensions).

•   Make sure the intake air is dry and dust-free.

•   Do not set up the compressor in damp or wet rooms. The 

compressor is designed to be used in dry rooms. It is prohibited 

to use the compressor in areas where work is conducted with 

sprayed water. 

•   Before you use the machine, make sure that the mains voltage 

complies with the specifications on the rating plate. 

•   The compressor may only be used in suitable areas (with good 

ventilation. There must be no dust, acids, vapours, explosive or 

flammable gases in the room.

WARNING! 

ENSURE THE TOOL IS TURNED OFF AND 

DISCONNECTED FROM THE POWER SUPPLY BEFORE 

PERFORMING ANY OF THE FOLLOWING OPERATIONS.

Summary of Contents for 40L 2.5HP

Page 1: ... If the tool is disassembled or tampered with in any way Professional industrial or high frequency use WARRANTY Ozito Industries Pty Ltd 25 Fox Drive Dandenong South Victoria Australia 3175 ozito com au 40L Air Compressor 2 x Wheels 2 x Large Bolts 4 x Large Washers 2 x Large Spring Washers 2 x Large Nuts 2 x Support Feet 2 x Small Bolts 4 x Washers 2 x Spring Washers 2 x Nuts 1021 IN ORDER TO MAK...

Page 2: ...ks Examine the machine for signs of transit damage If damaged do not use return to place of purchase The compressor should be set up near to the user Avoid long air lines and long supply lines extensions Make sure the intake air is dry and dust free Do not set up the compressor in damp or wet rooms The compressor is designed to be used in dry rooms It is prohibited to use the compressor in areas w...

Page 3: ...is secure by tugging gently on the connector If the hose detaches repeat steps 2 3 pushing the Nitto connector firmly into the outlet Disconnecting Air Tools 1 To remove an air tool from the unit retract the sleeve on the female Nitto fitting and disconnect the air hose from the air compressor 2 Repeat the same procedure with the air tool and air hose 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00...

Page 4: ...an attached blow gun to release some of the pressure until the tank pressure gauge drops below 6bar If the motor does not automatically start up the unit has overloaded and the thermal protection has activated If the thermal protection activates switch off the compressor and allow the compressor to cool down for 15 minutes before restarting WARNING ALLOW THE AIR COMPRESSOR TO COOL BEFORE ATTEMPTIN...

Page 5: ...0 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm AIR COMPRESSOR 2 0HP 40L 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kPA BAR PRESSURE GAUGE kg cm 0 25 50 75 10 0 125 15 0 0 1 00 3 00 5 00 7 00 9 00 2 4 6 8 10 Lb in PSI kP...

Page 6: ... PSI kPA BAR PRESSURE GAUGE kg cm AIR COMPRESSOR 2 5HP 40L Symptom Possible Cause Suggested Solution The compressor does not start Compressor has reached cut out pressure Compressor will automatically start once below the cut in pressure No power supply Check the power supply the power plug and the socket outlet Insufficient supply power Reduce length of extension lead Outside temperature is too l...

Page 7: ...g of the tool WARNING BEFORE CLEANING THE APPLIANCE OR CARRYING OUT ANY MAINTENANCE PROCEDURE MAKE SURE THAT IT IS DISCONNECTED FROM THE POWER SUPPLY TO PREVENT ACCIDENTAL STARTING Sound Power Level Wear hearing protection Warning Regulatory Compliance Mark RCM V Volts Hz W Hertz n0 min Alternating Current Watts No load speed Revolutions or reciprocations per minute Read Instruction Manual Beware ...

Page 8: ...t including safety goggles or shield ear protection breathing or respirator mask and protective clothing Never apply the outlet air of this compressor directly on to any part of a person s body Do not attempt to block the air outlet with your finger or any part of your body The tool must be used only for its prescribed purpose Any use other than those mentioned in this Manual will be considered a ...

Reviews: