- 13 -

• 

 Switch the appliance off when it is not in use.

• 

 Wear protective gloves.

Caution!

Residual risks

Even if you use this electric power tool in 

accordance with instructions, certain resi-

dual risks cannot be rules out. The following 

hazards may arise in connection with the 

equipment’s construction and layout:

1.   Damage to hearing if no suitable ear protec-

tion is used.

2.   Health damage caused by hand-arm vib-

rations if the equipment is used over a pro-

longed period or is not properly guided and 

maintained.

Danger! 

The electric power tool generates an electro-

magnetic 

fi

 eld during operation. Under certain 

circumstances this 

fi

 eld may actively or passively 

impede medical implants. To reduce the risk of 

serious or fatal injuries, we recommend persons 

with medical implants to consult their doctor and 

the manufacturer of the medical implant prior to 

using the equipment.

5. Before starting the equipment

Warning!

Always pull out the safety plug before performing 

any adjusting, repair, maintenance or cleaning 

work on the equipment.

The scari

fi

 er is delivered unassembled. The com-

plete push bar must be assembled and mounted 

before using the scari

fi

 er.

Follow the operating instructions step-by-step 

and use the pictures provided as a visual guide to 

easily assemble the machine.

Fitting the push bar holders 

(see Figs. 3 and 4)

Slide the push bar holders (Fig. 3/Item 7) into the 

provided openings (Fig. 3) and fasten them with 

the retaining screws (Fig. 4/Item 14).

Fitting the lower push bars (see Fig. 5)

• 

 Slide the lower push bars (Fig. 5/Item 6) onto 

the push bar holders.

• 

 Screw the tubes together, using the screws 

supplied (Fig. 5/Item 13). 

There are 3 assembly holes so that the height 

of the push bar can be adjusted to speci

fi

 c user 

requirements at any time. Use the hole which is 

best suited for you, making sure that you use the 

same hole on both sides.

Fitting the upper push bar (see Fig. 6)

• 

 Position the upper push bar (Fig. 1/Item 5) 

such that its holes line up with the holes of the 

lower bar.

• 

 Use the two socket head screws (Fig. 2/Item 

13) to screw the tubes together.

• 

 Use the cable clips (Fig. 7a/7b) to attach the 

power cable to the tubes of the push bars so 

that it is possible to open and shut the ejector 

flap.

Please ensure that the ejector 

fl

 ap can be opened 

and closed easily!

Fitting the optional catch basket (see Fig. 8)

The basic version of the equipment does not in-

clude a catch basket. This is available separately 

(Art. No. 3405577).

• 

 To hang the grass basket on the scarifier you 

must lift the ejector flap (Item 10) with one 

hand and with the other hand take hold of the 

grass bag by the handle and hook it onto the 

scarifier from above.

Danger! 

Before you ever hook the grass basket to the sca-

ri

fi

 er you must ensure that the motor is switched 

o

  and the cutting unit is not rotating.

Adjusting the working depth (see Fig. 9)

The scari

fi

 er depth is adjusted at the two front 

wheels using the adjustment mechanism. For this, 

pull out the adjusting screw and turn the wheel to 

the left or right into one of the available positions 

(0/1/2/3).

The scari

fi

 er depth must always be identically set 

on both sides!

0 = drive/transport position

1 = scari

fi

 er depth 3 mm

2 = scari

fi

 er depth 7 mm

3 = scari

fi

 er depth 9 mm

Anl_PXCLSS_0182U_SPK7.indb   13

Anl_PXCLSS_0182U_SPK7.indb   13

26.08.2019   09:51:49

26.08.2019   09:51:49

Summary of Contents for 3420661

Page 1: ...182U EH Art No 34 206 61 I No 11019 7 GB Original operating instructions Cordless Scarifier and Lawn Ae rator Anl_PXCLSS_0182U_SPK7 indb 1 Anl_PXCLSS_0182U_SPK7 indb 1 26 08 2019 09 51 24 26 08 2019 0...

Page 2: ...2 1 2 10 12 13 7 6 5 1 2 15 12 14 9 8 5 A 13 6 7 Anl_PXCLSS_0182U_SPK7 indb 2 Anl_PXCLSS_0182U_SPK7 indb 2 26 08 2019 09 51 29 26 08 2019 09 51 29...

Page 3: ...3 3 4 5 6 7a 7b 14 12 7 6 13 12 5 13 13 12 Anl_PXCLSS_0182U_SPK7 indb 3 Anl_PXCLSS_0182U_SPK7 indb 3 26 08 2019 09 51 29 26 08 2019 09 51 29...

Page 4: ...4 8 9 10 11 12 13 10 8 1 2 22 21 C B A B 15 15 Anl_PXCLSS_0182U_SPK7 indb 4 Anl_PXCLSS_0182U_SPK7 indb 4 26 08 2019 09 51 32 26 08 2019 09 51 32...

Page 5: ...5 14 15 16 17 18 19 1 A 2 5 A A 1 2 D A 2 1 Anl_PXCLSS_0182U_SPK7 indb 5 Anl_PXCLSS_0182U_SPK7 indb 5 26 08 2019 09 51 40 26 08 2019 09 51 40...

Page 6: ...6 98 20 A B C D F E G Anl_PXCLSS_0182U_SPK7 indb 6 Anl_PXCLSS_0182U_SPK7 indb 6 26 08 2019 09 51 48 26 08 2019 09 51 48...

Page 7: ...by our customer service Or examine the equipment for damage and carry out any necessary repairs to damaged parts And examine the equipment for loose parts and tighten them well Both hands must be on t...

Page 8: ...any rotating parts Keep clear of the chute opening at all times o Switch o the motor and pull the safety plug Make sure that all moving parts have reached a complete standstill 1 whenever you leave t...

Page 9: ...its electrical charac teristic curves are recorded These data are then used exclusively to be able to assemble the best possible battery packs Despite all the safety precautions caution must always b...

Page 10: ...have heated during the charging process as the battery cells may have su ered dangerous damage 11 Do not use batteries which have su ered curvature or deformation during the charging process or which...

Page 11: ...st time G Use only batteries which are charged to the same level 2 Layout and items supplied 2 1 Layout Fig 1 2 1 ON OFF switching bar 2 Safety lock o 5 Top push bar 6 Bottom push bar 7 Push bar brack...

Page 12: ...scarifier may not be used as a drive unit for other equipment or toolkits of any kind unless specifically advised to do so by the manufacturer The equipment is to be used only for its prescri bed pur...

Page 13: ...ush bar holders Screw the tubes together using the screws supplied Fig 5 Item 13 There are 3 assembly holes so that the height of the push bar can be adjusted to specific user requirements at any time...

Page 14: ...Open the battery cover This is done by pressing the lock B as shown in Fig 12 and swinging up the cover Then insert the two batteries in the mounts as shown in Fig 13 and push them for ward until the...

Page 15: ...see section 7 3 Tips on aerating properly with the aerator roller available as an option The way of working for aerating is the same as for scarifying You should therefore observe these safety inst ru...

Page 16: ...cement part number of the part required For our latest prices and information please go to www isc gmbh info Replacement cutting unit Art No 34 055 82 8 Storage and transport Storage Store the equipme...

Page 17: ...ery pack out of the charger Disconnect the charger from the mains supply Flashing O Adapted charging The charger is in gentle charging mode For safety reasons the charging is performed less quickly an...

Page 18: ...ttery and insert again see 5 Engine performance drops a Soil is too firm b Housing clogged c Roller badly worn a Change working depth b Clean housing c Replace roller Imprecise scarifying result a rol...

Page 19: ...cal equipment must make sure that the equipment is properly disposed of if he no longer wants to keep the equipment The old equipment can be returned to a suitable collection point that will dispose o...

Page 20: ...umables Category Example Wear parts V belt Roller Battery Consumables Missing parts Not necessarily included in the scope of delivery In the e ect of defects or faults please register the problem on t...

Page 21: ...nance Damage to the device caused by abuse or incorrect use for example overloading the device or the use or unapproved tools or accessories ingress of foreign bodies into the device such as sand ston...

Page 22: ...mi na podstawie dyrektywy WE BG LV paskaidro du atbilst bu ES direkt vai un standartiem LT apib dina atitikim EU reikalavimams ir prek s normoms RO declar urm toarea conformitate conform directivei UE...

Page 23: ...23 Anl_PXCLSS_0182U_SPK7 indb 23 Anl_PXCLSS_0182U_SPK7 indb 23 26 08 2019 09 51 50 26 08 2019 09 51 50...

Page 24: ...24 Anl_PXCLSS_0182U_SPK7 indb 24 Anl_PXCLSS_0182U_SPK7 indb 24 26 08 2019 09 51 50 26 08 2019 09 51 50...

Page 25: ...25 Anl_PXCLSS_0182U_SPK7 indb 25 Anl_PXCLSS_0182U_SPK7 indb 25 26 08 2019 09 51 50 26 08 2019 09 51 50...

Page 26: ...EH 08 2019 01 Anl_PXCLSS_0182U_SPK7 indb 26 Anl_PXCLSS_0182U_SPK7 indb 26 26 08 2019 09 51 50 26 08 2019 09 51 50...

Reviews: