background image

7 • Oz Charge manual 

 www.ozcharge.com.au

THE CHARGING PROCESS: LITHIUM

1)  Lithium Activation - Blue Charging LED Blinking

The charger sends a signal to wake up the Lithium battery management system (BMS) so it can 

detect the battery voltage and commence charging if safe to do so.

Note: 

If the Lithium Activation stage isn’t waking up the BMS (Blue charging LED isn’t coming 

on), you can activate power supply mode on the unit by holding the Charge Rate Button down 

for 3 seconds. 

Important

: After around 1 minute, press and hold the Charge Rate button again 

for 3 seconds to put the unit back into charging mode and the unit will commence charging.

2)  Soft Start Charging - Blue Charging LED Flashing

Gently charges the battery using a reduced charge output until the battery voltages reaches 

10V.   If the battery voltage doesn’t reach 10V within 6 hours, the safety timer protection will 

stop the unit from charging and the Charging, Full and Lithium LED’s will all flash.

3)  Bulk Charging - Blue Charging LED ON

Uses the maximum selected charge output until the battery voltage reaches 14V.                                        

If the battery voltage doesn’t reach 14V within 24 hours, the safety timer protection will stop the 

unit from charging and the Charging, Full and Lithium LED’s will all flash.

4)  Absorption Charging Stage 1 - Blue Charging LED ON and Green Full LED Flashing

Uses a constant voltage of 14V while reducing the charging output current to ensure the 

battery receives approximately 90% charge without overcharging the battery. 

5)  Absorption Charging Stage 2 - Blue Charging LED ON and Green Full LED Flashing

Steps up the constant voltage to 14.4V while reducing the charging output current to ensure 

the battery receives a full charge without overcharging the battery. 

6)  Float Mode - Full Green LED ON

Once the battery is fully charged, the Green Full LED will come on. The charger output will stop. 

However it will continue to monitor the battery condition as it will enter Long Term Analysis 

mode.

Long Term Analysis - Full Green LED ON

During long term analysis mode, the charger will monitor the battery level and reactivate the 

charger output if the voltage drops below 12.8V to ensure the battery is always ready when you 

need it. 

STEP 5 - Disconnecting the Battery charger from Battery

• 

If the Battery is out of the vehicle:

  

(1) Switch OFF and Remove the AC Power Socket from the outlet.

      

(2) Remove the Black lead and then the Red lead.

• 

If  the battery is still in the vehicle:

  

(1) Switch OFF and Remove the AC Power Socket from the outlet.

  

(2) Remove the lead from the vehicle chassis.

  

(3) Remove the lead from the battery.

Note: 

Check electrolyte levels if possible after charging as they may need topping up with distilled 

water.  (This does not apply to Sealed Maintenance Free batteries and Lithium type batteries)

 

 

Summary of Contents for OC-PRO2500L

Page 1: ...OWNER S MANUAL Model OC1206U OC1212U AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED OWNER S MANUAL Model OC PRO2500L AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED...

Page 2: ...ice agent or similarly qualified persons in order to avoid a hazard If battery acid contacts your skin or clothing wash immediately with soap and water If acid enters your eye immediately flush the ey...

Page 3: ...ully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance...

Page 4: ...tery charger has a built in ultra low power consumption circuit If AC power is connected and the battery is disconnected after 10 seconds the charger will automatically go into an ECO mode Both the se...

Page 5: ...age 13 6V lead acid type batteries only Power Supply Output 13 8VDC 25A Max StartVoltage 2V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Temp Compensation...

Page 6: ...he unit is turned on as per STEP 1 Note If the Fault Indicator LED illuminates Red please check your connections as it s likely that the Positive and Negative Leads are reversed If the Battery is out...

Page 7: ...ing Slow Single Flash Gently charges the battery using a reduced charge output until the battery voltages reaches 11V If the battery voltage doesn t reach 11V within 6 hours the safety timer protectio...

Page 8: ...1 Blue Charging LED ON and Green Full LED Flashing Uses a constant voltage of 14V while reducing the charging output current to ensure the battery receives approximately 90 charge without overcharging...

Page 9: ...rging Time Out Error ON OFF ON ON Flash Reverse Polarity or Short Circuit Error OFF OFF ON ON ON Final Analysis Sulphation Shorted cell check fail OverTemperature Protection OFF OFF ON ON Flash Power...

Page 10: ...9 Oz Charge manual www ozcharge com au CHARGING CURVE...

Page 11: ...ttery charger to a cooler environment The full float light won t come on Fault Red LED is Flashing or Full Green LED is Flashing Charging LED is ON Flashing with Fault LED flashing Battery Ah capacity...

Page 12: ...the customer should enclose a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as OzCharge Australia Pty Ltd Oz Charge accepts no respon...

Reviews: