background image

3 • Oz Charge manual 

 www.ozcharge.com.au

TEMPERATURE & SAFETY PROTECTION: 

• 

INTERNAL OVERHEAT PROTECTION: 

The charger has a built-in overheat and an overload 

electronic circuit. This protects the charger from being damage if overheated or overloaded 

and will automatically decrease the charging current. Once the units internal temperature 

decreases to a safe level, the charger will resume normal charging. 

• 

SAFETY TIMER PROTECTION: 

The charger has safety timers for every stage. If the battery 

voltage doesn’t reach a certain voltage within a certain time, the unit will stop charging as 

it’s highly likely that you’re attempting to charge a severely discharged or heavily sulphated 

battery. If any of the stages time out, the charger will immediately stop charging in order to 

protect the battery. This will be indicated  with the fault LED flashing slowly. 

• 

REVERSE POLARITY: 

The charger has reverse polarity protection. If the charger output leads 

are connected reverse polarity, the fault LED will come on and the charger will be disabled. 

Simply unplug  the charger from AC power and then connect the output leads to the correct 

polarity.

• 

SHORT CIRCUIT PROTECTION: 

The charger will automatically turn off if the output leads are 

short circuited and the fault LED will come on. This prevents the charger from being damaged 

if the positive and negative crocodile clips or the optional ring terminals accidentally touch each 

other while the charger is turned on.

• 

ECO MODE: 

This Oz Charge battery charger has a built in ultra low power consumption 

circuit. If AC power is connected and the battery is disconnected, after 10 seconds the charger 

will automatically go into an ECO mode. Both the selected Charge Rate and Battery Type LED’s 

will flash GREEN to indicate ECO mode. During this mode the power drawn is less than 0.5W 

which totals 0.01kWh per day power consumption. If AC power is connected and the battery 

is connected, once the battery is fully charged and during the long term maintenance stage, 

the total power consumption is around 0.03kWh per day.

Both the selected Charge rate and Battery type LED’s will flash GREEN to indicate ECO mode. 

• 

TEMPERATURE COMPENSATION: 

This Oz Charge battery charger comes with a temperature 

compensation sensor attached to the Negative Battery Clamp to ensure your batteries are 

charged at an optimum voltage. You’ll need to disconnect the temperature sensor from the 
unit output then connect the mating connector on the charging leads to the unit. If you’re 
using a different set of charging leads, leave the temperature sensor connected to the unit. 

BATTERY TYPES & CAPACITY:

• 

Suits 12V conventional lead acid batteries (VRLA) Gel, Calcium SMF, AGM, WET, EFB and 

compatible 

Lithium-ion (including LiFePO4) batteries

• 

The Ah (Ampere-hour) capacities shown below are to be used as a general guide only.

Some batteries may be able to handle a higher charge current. Refer to the battery 
manufacturers specifications and recommendations for your charging requirements. 

OC-PRO2500L

Charge Rate:

2A

15A

25A

Charging

15 - 40Ah

(290CCA)

45 - 300Ah

(2100CCA)

75 - 500Ah

(3600CCA)

Maintaining

< 120Ah

(870CCA)

< 450Ah

(3250CCA)

< 750Ah

(5400CCA)

Summary of Contents for OC-PRO2500L

Page 1: ...OWNER S MANUAL Model OC1206U OC1212U AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED OWNER S MANUAL Model OC PRO2500L AUSTRALIAN NEW ZEALAND STANDARD AS NZS 60335 2 29 APPROVED...

Page 2: ...ice agent or similarly qualified persons in order to avoid a hazard If battery acid contacts your skin or clothing wash immediately with soap and water If acid enters your eye immediately flush the ey...

Page 3: ...ully charged The battery charger can be left unattended and left permanently connected all year round The intelligent charger will monitor the battery voltage and will maintain it at peak performance...

Page 4: ...tery charger has a built in ultra low power consumption circuit If AC power is connected and the battery is disconnected after 10 seconds the charger will automatically go into an ECO mode Both the se...

Page 5: ...age 13 6V lead acid type batteries only Power Supply Output 13 8VDC 25A Max StartVoltage 2V OperatingTemperature 15 to 50 C StorageTemperature 25 to 85 C Operating Humidity 90 RH Max Temp Compensation...

Page 6: ...he unit is turned on as per STEP 1 Note If the Fault Indicator LED illuminates Red please check your connections as it s likely that the Positive and Negative Leads are reversed If the Battery is out...

Page 7: ...ing Slow Single Flash Gently charges the battery using a reduced charge output until the battery voltages reaches 11V If the battery voltage doesn t reach 11V within 6 hours the safety timer protectio...

Page 8: ...1 Blue Charging LED ON and Green Full LED Flashing Uses a constant voltage of 14V while reducing the charging output current to ensure the battery receives approximately 90 charge without overcharging...

Page 9: ...rging Time Out Error ON OFF ON ON Flash Reverse Polarity or Short Circuit Error OFF OFF ON ON ON Final Analysis Sulphation Shorted cell check fail OverTemperature Protection OFF OFF ON ON Flash Power...

Page 10: ...9 Oz Charge manual www ozcharge com au CHARGING CURVE...

Page 11: ...ttery charger to a cooler environment The full float light won t come on Fault Red LED is Flashing or Full Green LED is Flashing Charging LED is ON Flashing with Fault LED flashing Battery Ah capacity...

Page 12: ...the customer should enclose a copy of their receipt for proof of purchase It is recommended that returned products be sent by registered mail as OzCharge Australia Pty Ltd Oz Charge accepts no respon...

Reviews: