4 • Oz Charge manual
www.ozcharge.com.au
ELECTRICAL PARTS & ACCESSORIES:
AC Power Cord:
1.8m with SAA 3 Pin AU Plug
DC Output Lead:
250mm with 50A Anderson Connector & Temperature Compensa-
tion Sensor.
Charging Leads:
1.5m Integrated Crocodile Clips / Ring Terminals with Temperature
Compensation extension sensor.
Note
: To use the ring terminals
you’ll need an Alan key to remove the bolts from the crocodile clips
TECHNICAL SPECIFICATIONS:
Model Number
OC-PRO2500L
Output
25A @ 12V DC
Input Voltage
220-240Vac / 3.0A
Input Frequency
50Hz
Charge Voltage (25°C)
Gel - 14.1V
AGM&WET/EFB - 14.4V
Calcium - 14.7V
Lithium - 14.4V
Equalising Voltage
Gel - 14.3V
AGM&WET/EFB - 14.6V
Calcium - 15.5V
Float Voltage
13.6V (lead-acid type batteries only)
Power Supply Output
13.8VDC / 25A Max.
Start Voltage
2V
Operating Temperature -15 to 50°C
Storage Temperature
-25 to 85°C
Operating Humidity
90% RH Max.
Temp. Compensation
-25mV/°C
Size (L*W*H)
279mm x 141mm x 67mm
Weight
2 kg
Approvals
CE, AS/NZS, EMC
CHARGING INSTRUCTIONS:
STEP 1 - DETERMINE AND SELECT YOUR BATTERY TYPE BEFORE CONNECTING THE CHARGER
TO YOUR BATTERY. PLUG IN CHARGER AND TURN AC POWER ON. ONCE THE CORRECT
BATTERY TYPE AND CHARGE RATE IS SELECTED, SWITCH OFF AND UNPLUG BEFORE
CONNECTING THE CHARGER TO YOUR BATTERIES.
For conventional Lead acid type batteries including (VRLA) Gel, Calcium SMF, AGM&WET/EFB, press
the battery select button to illuminate the Green LED for your required battery type
.
For compatible Lithium-ion (LiFePO4) batteries, press the battery select button to illuminate the
Green LED for
Lithium
type battery selection.