8 • Oz Charge manual
www.ozcharge.com.au
LED STATUS INDICATOR TABLE:
Charging Mode Description
LED Indicators
Charging
Full
Selected
Battery
Type
Selected
Charge
Rate
Fault
Eco Mode - energy saving (no battery connected)
OFF
OFF
Flash
Flash
OFF
AC Power on - no battery connected / detected
OFF
OFF
ON
ON
OFF
Rejuvenation (Gel, Calcium, AGM&WET Battery
type selection only)
Double
Flash
OFF
ON
ON
OFF
Soft Start Charging
Single
Flash
OFF
ON
ON
OFF
Bulk Charging
ON
OFF
ON
ON
OFF
Absorption Charging
ON
Flash
ON
ON
OFF
Equalisation Charging
Flash
Flash
ON
ON
OFF
Full Float Maintenance mode
OFF
ON
ON
ON
OFF
Rejuvenation - Failed (Gel, Calcium, AGM&WET
Battery type selection only)
Double
Flash
OFF
ON
ON
ON
Soft Start Charging - Time Out Error
Single
Flash
OFF
ON
ON
Flash
Bulk Charging - Time Out Error
ON
OFF
ON
ON
Flash
Reverse Polarity or Short Circuit Error
OFF
OFF
ON
ON
ON
Final Analysis Sulphation / Shorted cell check fail.
Over Temperature Protection
OFF
OFF
ON
ON
Flash
Power Supply Mode Description
LED Indicators
Power Supply
Mode
25A
Fault
Power Supply Mode is ON.
ON
ON
OFF
Reverse Polarity / Short Circuit
ON
ON
ON
Note:
If the Battery Type and Charge Rate LED’s are both
flashing, this indicates no battery is detected or is below 2V
and the unit is in Eco Power Saving mode.
BATTERY TYPE / CHARGE RATE SETTING
To change battery type, press the Battery Select button.
To change the charge rate, press the Charge Rate button.
MANUAL REJUVENATION SETTING
For manual rejuvenation, press and hold the Battery Type
Button for 3 seconds. (This feature will not work for Lithium
type batteries. Only use for lead-acid type batteries.
POWER SUPPLY MODE - 13.8V / 25A Max Output
To activate Power Supply mode, press and hold the Charge
Rate Button for 3 seconds.
RED
BLACK
RED
CONNECTION IN VEHICLE
(
NEGATIVELY EARTHED
)
RED
BLACK
CONNECTION IN VEHICLE
(
POSITIVELY EARTHED
)
BLACK