7.2.
Changing the Photozone Lamp
1.
Turn off the Freshair via the flip switch (D) , the control light goes
off. Pull the power plug.
2
. Open the case (B) by loosening the four fastening screws (A) with the
aid of an allen wrench size
2,5
and then lift the cover.
3
. Pull the connection (G) from the used photozone lamp (H) and take it
out of the two lamps clips (I).
4
. Insert the new photozone lamp into the lamps clips and join it to the
connection.
5
. By pressing the reset button of the photozone lamp (F), reset the
operating hours counter to zero.
6
. Put the cover back on the case and afterwards lock it back on with the
four fastening screws.
The air purification device is now ready to use again.
Warning!
UV-C Radiation
• Before opening the case of the Freshair, the device must be
switched off and electricity supply disconnected from the power
plug.
• When opening the case during running operation, there is the danger
of optical radiation through UV rays. This can lead to extremely
painful conjunctivitis and skin irritations!